EasyManua.ls Logo

Mitsubishi Electric FR-A840-04320 (160K) User Manual

Mitsubishi Electric FR-A840-04320 (160K)
856 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INVERTER
INVERTER FR-A800 INSTRUCTION MANUAL (DETAILED)
J
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
IB(NA)-0600503ENG-J(1705)MEE Printed in Japan Specifications subject to change without notice.
FR-A800
INSTRUCTION MANUAL (DETAILED)
FR-A820-00046(0.4K) to 04750(90K)(-GF)
FR-A840-00023(0.4K) to 06830(280K)(-GF)
FR-A842-07700(315K) to 12120(500K)(-GF)
FR-A846-00023(0.4K) to 03610(132K)
High functionality and high performance
MODEL
FR-A800
INSTRUCTION MANUAL
MODEL
CODE
XXX-XXX
Model
FR-A800
Instruction Manual (Detailed)
Model code 1A2-P52

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-A840-04320 (160K) Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-A840-04320 (160K)
CategoryInverter
LanguageEnglish

Summary

Chapter 2 Installation and Wiring

2.4 Terminal connection diagrams

Illustrates the wiring diagrams for connecting various terminals to the inverter.

Chapter 3 Precautions for Use of the Inverter

3.6 Checklist before starting operation

A checklist of crucial points to verify before commencing inverter operation.

Chapter 4 Basic Operation

4.5 Basic operation procedure (PU operation)

Provides step-by-step instructions for basic inverter operation using the PU (operation panel).

4.6 Basic operation procedure (External operation)

Provides step-by-step instructions for basic inverter operation using external signals.

Chapter 5 Parameters

5.1 Parameter list

Lists all parameters, their initial values, setting ranges, and descriptions.

5.2 Control method

Describes the available control methods: V/F, Advanced magnetic flux vector, Real sensorless vector, Vector, and PM sensorless vector.

5.3 Speed control under Real sensorless vector control, Vector control, PM sensorless vector control

Details speed control procedures for Real sensorless vector, Vector, and PM sensorless vector control.

5.4 Torque control under Real sensorless vector control and Vector control

Explains torque control procedures under Real sensorless vector control and Vector control.

5.5 Position control under vector control and PM sensorless vector control

Covers position control settings for Vector control and PM sensorless vector control.

5.8 (F) Setting of acceleration/deceleration time and acceleration/deceleration pattern

Details settings for acceleration/deceleration times and patterns.

5.9 (D) Operation command and frequency command

Explains how to set operation modes and frequency command sources.

5.10 (H) Protective function parameter

Details all protective functions to ensure safe and reliable operation.

5.13 (C) Motor constant parameters

Provides parameters for setting motor constants, including auto tuning.

5.14 (A) Application parameters

Describes parameters for specific application functions.

5.15 (N) Communication operation parameters

Covers parameters for communication setup and operation.

5.16 (G) Control parameters

Details parameters for various control methods like V/F, Vector, and PM.

Chapter 6 Protective Functions

6.1 Inverter fault and alarm indications

Explains the fault and alarm indications displayed by the inverter.

6.5 Causes and corrective actions

Details common causes of faults and provides corresponding corrective actions.

Chapter 7 Precautions for Maintenance and Inspection

Related product manuals