INVERTER
INVERTER FR-A800 INSTRUCTION MANUAL (DETAILED)
J
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
IB(NA)-0600503ENG-J(1705)MEE Printed in Japan Specifications subject to change without notice.
FR-A800
INSTRUCTION MANUAL (DETAILED)
FR-A820-00046(0.4K) to 04750(90K)(-GF)
FR-A840-00023(0.4K) to 06830(280K)(-GF)
FR-A842-07700(315K) to 12120(500K)(-GF)
FR-A846-00023(0.4K) to 03610(132K)
High functionality and high performance
MODEL
FR-A800
INSTRUCTION MANUAL
MODEL
CODE
XXX-XXX
Model
FR-A800
Instruction Manual (Detailed)
Model code 1A2-P52

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-A840-00380 (15K) Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-A840-00380 (15K)
CategoryInverter
LanguageEnglish

Summary

INVERTER FR-A800 INSTRUCTION MANUAL (DETAILED)

CHAPTER 2 INSTALLATION AND WIRING

2.3 Installation of the inverter and enclosure design

Guidelines for installing the inverter and designing the enclosure for optimal performance and safety.

CHAPTER 4 BASIC OPERATION

4.5 Basic operation procedure (PU operation)

Step-by-step instructions for basic operations using the PU (operation panel).

4.6 Basic operation procedure (External operation)

Step-by-step instructions for basic operations using external signals.

CHAPTER 5 PARAMETERS

5.2 Control method

Explains the different control methods available for the inverter, including V/F, Vector, and PM sensorless control.

5.3 Speed control under Real sensorless vector control, vector control, PM sensorless vector control

Details on performing speed control using Real sensorless vector control, Vector control, and PM sensorless vector control.

5.4 Torque control under Real sensorless vector control and Vector control

Explains torque control methods for Real sensorless vector control and Vector control.

5.5 Position control under vector control and PM sensorless vector control

Details on performing position control using Vector control and PM sensorless vector control.

5.8 (F) Setting of acceleration/deceleration time and acceleration/deceleration pattern

Explains how to set acceleration/deceleration times and patterns for optimal motor response.

5.9 (D) Operation command and frequency command

Details on setting operation commands and frequency commands for the inverter.

CHAPTER 6 PROTECTIVE FUNCTIONS

6.1 Inverter fault and alarm indications

Lists and describes the fault and alarm indications displayed by the inverter.

6.2 Reset method for the protective functions

Explains the procedure for resetting protective functions after a fault or alarm.

6.4 List of fault displays

Provides a list of all possible fault displays and their corresponding descriptions.

6.5 Causes and corrective actions

Details common causes of inverter faults and alarms, along with their corrective actions.

6.6 Check first when you have a trouble

Troubleshooting guide for common inverter issues and possible causes.

CHAPTER 7 PRECAUTIONS FOR MAINTENANCE AND INSPECTION

Related product manuals