EasyManua.ls Logo

Mitsubishi Electric FR-A840-00170 (5.5K) User Manual

Mitsubishi Electric FR-A840-00170 (5.5K)
856 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INVERTER
INVERTER FR-A800 INSTRUCTION MANUAL (DETAILED)
J
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
IB(NA)-0600503ENG-J(1705)MEE Printed in Japan Specifications subject to change without notice.
FR-A800
INSTRUCTION MANUAL (DETAILED)
FR-A820-00046(0.4K) to 04750(90K)(-GF)
FR-A840-00023(0.4K) to 06830(280K)(-GF)
FR-A842-07700(315K) to 12120(500K)(-GF)
FR-A846-00023(0.4K) to 03610(132K)
High functionality and high performance
MODEL
FR-A800
INSTRUCTION MANUAL
MODEL
CODE
XXX-XXX
Model
FR-A800
Instruction Manual (Detailed)
Model code 1A2-P52

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-A840-00170 (5.5K) Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-A840-00170 (5.5K)
CategoryInverter
LanguageEnglish

Summary

Chapter 1 Introduction

1.3 Operation steps

Provides a step-by-step guide for initial setup, installation, wiring, and basic operation.

Chapter 2 Installation and Wiring

2.3 Installation of the inverter and enclosure design

Covers the structure, size, device layout, and environmental conditions for inverter installation.

2.4 Terminal connection diagrams

Provides detailed wiring diagrams for connecting power supply, motor, and control circuits.

2.5 Main circuit terminals

Details the specifications and functions of the main circuit terminals.

2.6 Control circuit

Explains the wiring and configuration of the control circuit terminals.

2.8 Connection to a motor with encoder (Vector control)

Explains wiring for encoder-equipped motors for Vector control operation.

2.9 Parameter settings for a motor with encoder

Details the parameters necessary for setting up a motor with an encoder for Vector control.

Chapter 3 Precautions for Use of the Inverter

3.4 Power shutdown and magnetic contactor (MC)

Covers the importance of magnetic contactors for safe power shutdown and preventing accidents.

3.6 Checklist before starting operation

A checklist of critical points to verify before starting inverter operation to ensure safety and product life.

3.7 Failsafe system which uses the inverter

Explains how to implement failsafe measures using inverter status output signals and external systems.

Chapter 4 Basic Operation

4.1 Operation panel (FR-DU08)

Introduces the components and basic functions of the FR-DU08 operation panel.

4.3 Easy setting of the inverter operation mode

Guides users on how to easily set the inverter operation mode using Pr.79.

4.4 Frequently-used parameters (simple mode parameters)

Lists and explains frequently used parameters grouped as simple mode parameters.

4.5 Basic operation procedure (PU operation)

Provides step-by-step instructions for basic inverter operation using the PU.

4.6 Basic operation procedure (External operation)

Provides step-by-step instructions for basic inverter operation using external signals.

4.7 Basic operation procedure (JOG operation)

Details how to perform basic JOG operation using external signals or the operation panel.

Chapter 5 Parameters

Chapter 6 Protective Functions

Chapter 7 Precautions for Maintenance and Inspection

Related product manuals