EasyManua.ls Logo

Mitsubishi Electric FR-E740-2.2K User Manual

Mitsubishi Electric FR-E740-2.2K
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
3
4
5
6
7
1
2
FR-E700
INSTRUCTION MANUAL (Applied)
INVERTER
PRECAUTIONS FOR USE
OF THE INVERTER
PARAMETERS
TROUBLESHOOTING
PRECAUTIONS FOR
MAINTENANCE AND INSPECTION
SPECIFICATIONS
OUTLINE
WIRING
MODEL
MODEL
CODE
1A2-P26
FR-E700
INSTRUCTION MANUAL (Applied)
FR-E720-0.1K to 15K
FR-E740-0.4K to 15K
FR-E720S-0.1K to 2.2K
FR-E710W-0.1K to 0.75K
IB(NA)-0600277ENG-D (0812)MEE Printed in Japan Specifications subject to change without notice.
FR-E700 INVERTER INSTRUCTION MANUAL (Applied)
D

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-E740-2.2K Specifications

General IconGeneral
ModelFR-E740-2.2K
SeriesFR-E700
Applicable Motor Capacity (kW)2.2
Output Power2.2 kW
Output Voltage3-phase 380 to 480 V
Overload Capacity150% for 60 seconds
Protection LevelIP20
Weight1.5 kg
Control MethodPWM Control
Output Frequency Range0.2 to 400 Hz
Frequency Range0.2 to 400 Hz
Protection StructureIP20
Input Voltage3-phase 380 to 480 V

Summary

PRECAUTIONS FOR USE OF THE INVERTER

Precautions for use of the inverter

Lists essential safety and handling precautions for general inverter operation, wiring, and environment.

PARAMETERS

Parameter list

Provides a comprehensive list of inverter parameters, their settings, instruction codes, and related pages.

Adjust the output torque (current) of the motor

Details methods to adjust motor torque, including manual boost, slip compensation, and stall prevention.

Selection and protection of a motor

Guides on selecting motors, implementing protection mechanisms, and performing auto-tuning.

Motor brake and stop operation

Details methods for motor braking and stopping, including DC injection, regenerative braking, and stop-on-contact.

Function assignment of external terminal and control

Explains how to assign functions to input and output terminals and select control signals for various operations.

Operation selection at power failure and instantaneous power failure

Covers automatic restart, deceleration, and operation continuation functions during power interruptions.

Operation setting at fault occurrence

Details settings for handling faults, including retry functions, phase loss protection, and earth fault detection.

Selection of operation mode and operation location

Explains how to select and manage different operation modes (PU, External, Network) and their control sources.

TROUBLESHOOTING

Reset method of protective function

Explains procedures to reset protective functions and recover from faults using operation panel or signals.

List of fault or alarm indications

Provides a comprehensive list of fault codes, indications, and their corresponding reference pages.

Causes and corrective actions

Details common causes of operational issues like error messages, warnings, alarms, and faults with corrective actions.

Check first when you have some troubles

Offers initial checks for common problems like motor not starting, abnormal noise, or improper operation mode.