2
FR-E700
INSTRUCTION MANUAL
INVERTER
PRECAUTIONS FOR USE
OF THE INVERTER
PARAMETERS
TROUBLESHOOTING
PRECAUTIONS FOR
MAINTENANCE AND INSPECTION
SPECIFICATIONS
OUTLINE
WIRING
FR-E720-008(SC) to 600(SC) - NA
FR-E740-016(SC) to 300(SC) - NA
FR-E720S-008 to 110 - NA
FR-E710W-008 to 050 - NA
IB(NA)-0600334ENG-D (1010)MEE Printed in Japan Specifications subject to change without notice.
FR-E700-NA INVERTER INSTRUCTION MANUAL
D

Table of Contents

Other manuals for Mitsubishi Electric FR-E740-026

Questions and Answers

  • S
    Samuel TownsendSep 22, 2025
    What to do if Mitsubishi Electric FR-E740-026 has PU stop?
    • Z
      Zachary GlennSep 22, 2025
      If the Mitsubishi Electric Inverter experiences a PU stop, turn the start signal off and release.
  • D
    Darrell MillerAug 23, 2025
    What to do if Mitsubishi Electric Inverter trips due to overcurrent during acceleration?
    • J
      Julie SalasAug 23, 2025
      Here are some possible solutions: 1. Increase the acceleration time. 2. If "E.OC1" is continuously lit at startup, disconnect the motor and then start the inverter. 3. Inspect the wiring to ensure there is no output short circuit or ground fault. 4. Enable stall prevention operation. 5. Set the base voltage (rated voltage of the motor) in Pr. 19 Base frequency voltage.
  • P
    Paula FinleyAug 25, 2025
    How to fix write disable error on Mitsubishi Electric FR-E740-026?
    • T
      tammy68Aug 26, 2025
      A write disable error on your Mitsubishi Electric Inverter may occur due to several reasons: * If Pr. 77 Parameter write selection is set to disable parameter write, check this setting. * If the frequency jump setting range is overlapping, review the settings of Pr. 31 to Pr. 36 (frequency jump). * If the PU and inverter are not communicating correctly, verify the connection between the PU and the inverter.
  • C
    Charles CantuAug 26, 2025
    What to do if Mitsubishi Electric FR-E740-026 shows regenerative brake prealarm?
    • J
      josephmarquezAug 26, 2025
      If you're seeing a regenerative brake prealarm on your Mitsubishi Electric Inverter: 1. Try increasing the deceleration time. 2. Make sure that the Pr. 30 Regenerative function selection and Pr. 70 Special regenerative brake duty settings are configured correctly.
  • D
    Dr. Michael BaldwinAug 27, 2025
    Why is Mitsubishi Electric Inverter showing electronic thermal relay function prealarm?
    • C
      cynthia47Aug 27, 2025
      If your Mitsubishi Electric Inverter is showing an electronic thermal relay function prealarm: 1. Reduce the load and frequency of operation. 2. Set an appropriate value in Pr. 9 Electronic thermal O/L relay.
  • L
    Levi RobinsonSep 18, 2025
    How to resolve calibration error on Mitsubishi Electric FR-E740-026 Inverter?
    • G
      gsmithSep 18, 2025
      To address a calibration error on your Mitsubishi Electric Inverter, check the settings of C3, C4, C6, and C7 (calibration functions).
  • J
    Jerry WellsSep 15, 2025
    What to do if Mitsubishi Electric Inverter has analog input fault?
    • M
      Melvin RoySep 15, 2025
      If your Mitsubishi Electric Inverter is showing an analog input fault, either provide a frequency command via current input or set Pr. 267 Terminal 4 input selection, and voltage/current input switch to voltage input.
  • D
    davispatrickSep 16, 2025
    How to resolve mode designation error on Mitsubishi Electric FR-E740-026?
    • J
      Jerry SullivanSep 16, 2025
      To resolve a mode designation error on your Mitsubishi Electric Inverter, ensure you make parameter settings after setting the operation mode to the "PU operation mode", or after setting "2" in Pr. 77.
  • C
    Courtney ChristianSep 6, 2025
    How to fix ground fault on Mitsubishi Electric FR-E740-026 Inverter?
    • D
      Dennis RossSep 7, 2025
      To fix a ground fault on your Mitsubishi Electric Inverter, locate and repair the ground fault.
  • J
    Jennifer HaleSep 3, 2025
    What to do if Mitsubishi Electric FR-E740-026 Inverter shows input phase loss?
    • M
      monica23Sep 4, 2025
      If your Mitsubishi Electric Inverter indicates an input phase loss: * Ensure the cables are wired correctly. * Repair any breaks in the cable. * Verify the Pr. 872 Input phase loss protection selection setting.

Summary

1 OUTLINE

1.1 Product Checking and Parts Identification

Unpacking and verifying inverter components and rating plates.

2 WIRING

2.1 Wiring

Basic wiring procedures, including terminal connection diagrams for standard and safety stop models.

2.2 Main Circuit Terminal Specifications

Details on main circuit terminals, power supply, and motor wiring arrangements for different inverter series.

3 PRECAUTIONS FOR USE OF THE INVERTER

3.1 EMC and Leakage Currents

Guidance on minimizing electromagnetic interference and managing leakage currents for safe operation.

3.5 Precautions for Use of the Inverter

Essential safety guidelines and operational precautions to prevent product damage or shortened lifespan.

4 PARAMETERS

4.2 Parameter List

A comprehensive list of all inverter parameters, their settings, and related pages for detailed explanation.

4.4 Adjustment of the Output Torque (Current) of the Motor

Details on adjusting motor torque using boost, slip compensation, and stall prevention functions.

4.8 Setting of Acceleration;Deceleration Time and Acceleration; Deceleration Pattern

Configuration of acceleration, deceleration times, and patterns for smooth motor start-up and stop.

4.9 Selection and Protection of a Motor

Guidance on motor selection, overheat protection, and using auto-tuning for optimal performance.

5 TROUBLESHOOTING

5.1 Reset Method of Protective Function

Procedures for resetting inverter protective functions after faults or warnings.

5.2 List of Fault or Alarm Indications

A comprehensive list of all fault and alarm codes with their corresponding names and page references.

5.3 Causes and Corrective Actions

Detailed troubleshooting guide for common error messages, warnings, and faults with suggested corrective actions.

5.5 Check First When You Have a Trouble

A systematic checklist for diagnosing common operational issues like motor not starting or speed variations.

6 PRECAUTIONS FOR MAINTENANCE AND INSPECTION

7 SPECIFICATIONS

Mitsubishi Electric FR-E740-026 Specifications

General IconGeneral
ModelFR-E740-026
SeriesFR-E700
Frequency Range50/60Hz
Protection ClassIP20
Output Frequency Range0-400Hz
Control MethodV/f control, Vector control
Protection StructureOpen type
Overload current rating150% for 60 seconds
Cooling methodFan cooled
Operating temperature-10°C to +50°C
Storage temperature-20°C to +65°C
Ambient humidity95% RH or less (non-condensing)
Vibration resistance5.9 m/s²
CommunicationRS-485