EasyManua.ls Logo

Mitsubishi Electric FR-E740-0.4K User Manual

Mitsubishi Electric FR-E740-0.4K
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
3
4
5
6
7
1
2
FR-E700
INSTRUCTION MANUAL (Applied)
INVERTER
PRECAUTIONS FOR USE
OF THE INVERTER
PARAMETERS
TROUBLESHOOTING
PRECAUTIONS FOR
MAINTENANCE AND INSPECTION
SPECIFICATIONS
OUTLINE
WIRING
MODEL
MODEL
CODE
1A2-P26
FR-E700
INSTRUCTION MANUAL (Applied)
FR-E720-0.1K to 15K
FR-E740-0.4K to 15K
FR-E720S-0.1K to 2.2K
FR-E710W-0.1K to 0.75K
IB(NA)-0600277ENG-D (0812)MEE Printed in Japan Specifications subject to change without notice.
FR-E700 INVERTER INSTRUCTION MANUAL (Applied)
D

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-E740-0.4K Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-E740-0.4K
CategoryInverter
LanguageEnglish

Summary

WIRING

PRECAUTIONS FOR USE OF THE INVERTER

3.1 EMC and leakage currents

Measures for electromagnetic compatibility and managing leakage currents to prevent noise and malfunctions.

3.5 Precautions for use of the inverter

General safety precautions and handling instructions to prevent product damage or personal injury.

3.6 Failsafe of the system which uses the inverter

Methods for implementing failsafe systems using inverter status output signals and external backup methods.

PARAMETERS

4.4 Adjust the output torque (current) of the motor

Parameters and methods for adjusting motor torque, including manual torque boost and stall prevention.

4.9 Selection and protection of a motor

Motor protection features like overheat protection and selection of motor constants for optimal performance.

4.10 Motor brake and stop operation

Methods for implementing DC injection braking, regenerative braking, and various stop functions.

4.11 Function assignment of external terminal and control

How to assign functions to input and output terminals for control and monitoring.

4.14 Operation setting at fault occurrence

Configuration of retry functions, phase loss protection, and earth fault detection.

TROUBLESHOOTING

5.1 Reset method of protective function

Procedures for resetting the inverter after faults or warnings, including power cycle and RES signal methods.

5.2 List of fault or alarm indications

A comprehensive list of inverter fault and alarm codes, their indications, and corresponding pages for details.

5.3 Causes and corrective actions

Troubleshooting guide for common error messages, warnings, and faults with suggested corrective actions.

5.5 Check first when you have some troubles

Initial checks and troubleshooting steps for common issues like motor not starting or abnormal noise.