FR-E700
INSTRUCTION MANUAL (Applied)
INVERTER
PRECAUTIONS FOR USE
OF THE INVERTER
PARAMETERS
TROUBLESHOOTING
PRECAUTIONS FOR
MAINTENANCE AND INSPECTION
SPECIFICATIONS
OUTLINE
WIRING
MODEL
MODEL
CODE
1A2-P26
FR-E700
INSTRUCTION MANUAL (Applied)
FR-E720-0.1K to 15K
FR-E740-0.4K to 15K
FR-E720S-0.1K to 2.2K
FR-E710W-0.1K to 0.75K
IB(NA)-0600277ENG-D (0812)MEE Printed in Japan Specifications subject to change without notice.
FR-E700 INVERTER INSTRUCTION MANUAL (Applied)
D

Table of Contents

Questions and Answers

  • K
    Kathleen TranSep 10, 2025
    How to unlock password on Mitsubishi Electric FR-E740-0.4K?
    • M
      Matthew HoustonSep 10, 2025
      If the Mitsubishi Electric Inverter is password locked, enter the password in Pr. 297 Password lock/unlock to unlock the password function before operating.
  • M
    Michael ObrienAug 25, 2025
    How to resolve overcurrent trip during deceleration or stop on Mitsubishi Electric FR-E740-0.4K Inverter?
    • J
      Jeffrey MorenoAug 25, 2025
      If the Mitsubishi Electric Inverter experiences an overcurrent trip during deceleration or stop, it signifies that an overcurrent has occurred during these phases. Here’s what you can do: * Increase the deceleration time. * Check the wiring for output short circuits or ground faults. * Verify that the mechanical brake isn't activating too early. * Lower the stall prevention operation level. * Activate the stall prevention operation and the fast-response current limit operation (Pr.156). * If the motor is coasting, stop it before issuing a start command. Alternatively, use the automatic restart after instantaneous power failure/flying start function.
  • V
    velasquezjoseAug 27, 2025
    How to fix regenerative overvoltage trip during deceleration or stop on Mitsubishi Electric FR-E740-0.4K Inverter?
    • E
      Ethan HaleAug 27, 2025
      If your Mitsubishi Electric Inverter is tripping due to regenerative overvoltage during deceleration or stop, it means overvoltage has occurred. Try these solutions: * Increase the deceleration time to match the load's moment of inertia. * Make the brake cycle longer. * Use the regeneration avoidance function (Pr. 882, Pr. 883, Pr.885, Pr.886). * Consider using a brake resistor, brake unit, or power regeneration common converter (FR-CV) as needed.
  • J
    Jimmy RiveraAug 27, 2025
    How to resolve regenerative overvoltage trip during acceleration on Mitsubishi Electric FR-E740-0.4K Inverter?
    • M
      matthewjohnsonAug 28, 2025
      If your Mitsubishi Electric Inverter is tripping due to regenerative overvoltage during acceleration, it means overvoltage has occurred during acceleration. Here are some steps to take: * Decrease the acceleration time. * Implement the regeneration avoidance function using parameters Pr. 882, Pr. 883, Pr.885, and Pr. 886. * Ensure that the stall prevention operation level (Pr. 22) is set correctly.
  • D
    David FranklinAug 29, 2025
    What to do if Mitsubishi Electric Inverter shows inverter overload trip?
    • S
      Shannon HernandezAug 29, 2025
      If the Mitsubishi Electric Inverter experiences an overload trip (electronic thermal O/L relay function), it signifies that the electronic thermal relay function for inverter element protection has been activated. To address this: * Increase the acceleration time. * Adjust the torque boost setting (Pr. 0). * Configure the load pattern selection setting (Pr. 14) according to the machine's load pattern. * Reduce the load. * Ensure the surrounding air temperature is within specified limits.
  • S
    strongamberNov 20, 2025
    How to fix overcurrent trip during acceleration on Mitsubishi Electric FR-E740-0.4K?
    • M
      markmartinNov 20, 2025
      If the Mitsubishi Electric Inverter experiences an overcurrent trip during acceleration, it means that an overcurrent has occurred. To resolve this, try the following: * Increase the acceleration time. * Check for output short circuits or ground faults in the wiring. * If 'E.OC1' appears consistently at start, disconnect and restart the inverter. If the problem persists, the inverter may be faulty and you should contact your sales representative. * Ensure the base frequency is correctly set (Pr. 3) for your motor (50Hz). * Reduce the stall prevention operation level and activate both stall prevention and fast-response current limit operations (Pr.156). * For regenerative driving, adjust the base voltage in Pr. 19. * If the motor is coasting, stop it before issuing a start co...
  • D
    Debra FlynnSep 18, 2025
    What does fan alarm mean on Mitsubishi Electric Inverter?
    • M
      moorenatalieSep 18, 2025
      If the Mitsubishi Electric Inverter triggers a fan alarm, it indicates that the cooling fan is at a standstill or has decelerated. Check for fan failure and contact your sales representative.
  • D
    Dana AlexanderSep 22, 2025
    What to do if Mitsubishi Electric FR-E740-0.4K shows brake transistor alarm detection?
    • J
      jennifer72Sep 22, 2025
      If the Mitsubishi Electric Inverter detects a fault in the brake circuit, such as a brake transistor breakage, replace the inverter.
  • M
    Michael HarmonSep 8, 2025
    What causes output phase loss in Mitsubishi Electric Inverter?
    • S
      Samuel SimpsonSep 8, 2025
      If the Mitsubishi Electric Inverter detects a loss in one of the three output phases (U, V, W) during operation, ensure the cables are properly wired. If the motor capacity is smaller than the inverter capacity, choose matching inverter and motor capacities.
  • A
    Ashley GordonSep 5, 2025
    What to do if Mitsubishi Electric Inverter shows regenerative brake pre-alarm?
    • F
      Frederick WilsonSep 5, 2025
      If the Mitsubishi Electric Inverter's regenerative brake duty reaches 85% of the Pr. 70 Special regenerative brake duty setting or higher, set a longer deceleration time and check the settings of Pr.30 Regenerative function selection and Pr. 70 Special regenerative brake duty.

Summary

WIRING

PRECAUTIONS FOR USE OF THE INVERTER

3.1 EMC and leakage currents

Measures for electromagnetic compatibility and managing leakage currents to prevent noise and malfunctions.

3.5 Precautions for use of the inverter

General safety precautions and handling instructions to prevent product damage or personal injury.

3.6 Failsafe of the system which uses the inverter

Methods for implementing failsafe systems using inverter status output signals and external backup methods.

PARAMETERS

4.4 Adjust the output torque (current) of the motor

Parameters and methods for adjusting motor torque, including manual torque boost and stall prevention.

4.9 Selection and protection of a motor

Motor protection features like overheat protection and selection of motor constants for optimal performance.

4.10 Motor brake and stop operation

Methods for implementing DC injection braking, regenerative braking, and various stop functions.

4.11 Function assignment of external terminal and control

How to assign functions to input and output terminals for control and monitoring.

4.14 Operation setting at fault occurrence

Configuration of retry functions, phase loss protection, and earth fault detection.

TROUBLESHOOTING

5.1 Reset method of protective function

Procedures for resetting the inverter after faults or warnings, including power cycle and RES signal methods.

5.2 List of fault or alarm indications

A comprehensive list of inverter fault and alarm codes, their indications, and corresponding pages for details.

5.3 Causes and corrective actions

Troubleshooting guide for common error messages, warnings, and faults with suggested corrective actions.

5.5 Check first when you have some troubles

Initial checks and troubleshooting steps for common issues like motor not starting or abnormal noise.