EasyManua.ls Logo

Mitsubishi Electric FR-E740-3.7K(SC) User Manual

Mitsubishi Electric FR-E740-3.7K(SC)
349 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
3
4
5
6
7
1
2
FR-E700
INSTRUCTION MANUAL (Applied)
INVERTER
PRECAUTIONS FOR USE
OF THE INVERTER
PARAMETERS
TROUBLESHOOTING
PRECAUTIONS FOR
MAINTENANCE AND INSPECTION
SPECIFICATIONS
OUTLINE
WIRING
MODEL
MODEL
CODE
1A2-P26
FR-E700
INSTRUCTION MANUAL (Applied)
FR-E720-0.1K(SC) to 15K(SC)
FR-E740-0.4K(SC) to 15K(SC)
FR-E720S-0.1K(SC) to 2.2K(SC)
FR-E710W-0.1K to 0.75K
IB(NA)-0600277ENG-F (1009)MEE Printed in Japan Specifications subject to change without notice.
INVERTER FR-E700 INSTRUCTION MANUAL (Applied)
F

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-E740-3.7K(SC) Specifications

General IconGeneral
ModelFR-E740-3.7K(SC)
SeriesFR-E700
TypeInverter
Rated Output Power3.7 kW
Horsepower5 HP
Rated Current8.5 A
Input Frequency50/60 Hz
Protection LevelIP20
Cooling MethodFan Cooled
Humidity95% RH or less (non-condensing)
Input Voltage3-phase 380-480V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage
Operating Temperature-10 to +50 °C
Storage Temperature-20 to +65 °C
AltitudeUp to 1000 m

Summary

OUTLINE

WIRING

PRECAUTIONS FOR USE OF THE INVERTER

3.1 EMC and leakage currents

Addresses electromagnetic compatibility (EMC) and leakage currents, including measures to suppress noise and ensure safe operation.

3.5 Precautions for use of the inverter

General safety precautions for operating the inverter, covering wiring, handling, and environmental considerations.

PARAMETERS

4.2 Parameter list

A comprehensive list of all parameters, including their numbers, names, setting ranges, and descriptions for configuration.

4.4 Adjustment of the output torque (current) of the motor

Details how to adjust motor torque characteristics, including torque boost, slip compensation, and stall prevention.

4.8 Setting of acceleration/deceleration time and acceleration/deceleration pattern

Covers setting acceleration and deceleration times, patterns, and related functions for smooth motor control.

4.9 Selection and protection of a motor

Guidance on selecting the appropriate motor and implementing protection features like overheat protection.

4.10 Motor brake and stop operation

Details on motor braking methods, including DC injection brake, regenerative braking, and stop-on-contact control.

4.11 Function assignment of external terminal and control

Explains how to assign functions to external input and output terminals for flexible control.

4.13 Operation selection at power failure and instantaneous power failure

Covers automatic restart and power failure deceleration functions for reliable operation during power interruptions.

4.14 Operation setting at fault occurrence

Details how to configure retry functions and manage fault occurrences to ensure continuous operation.

4.18 Misoperation prevention and parameter setting restriction

Covers functions for preventing misoperation, such as reset selection, parameter write protection, and password lock.

TROUBLESHOOTING

5.1 Reset method of protective function

Describes methods for resetting protective functions and recovering the inverter after a fault.

5.2 List of fault or alarm indications

Provides a comprehensive list of fault and alarm codes displayed on the operation panel and their meanings.

5.3 Causes and corrective actions

Details common causes of faults and alarms, along with recommended corrective actions for troubleshooting.

PRECAUTIONS FOR MAINTENANCE AND INSPECTION

SPECIFICATIONS

Related product manuals