APPX
Appendix 1 Operations of when the MC/MCR instructions are used to control EN
115
A
Timer (low-speed timer/timer/high-speed timer)
The following describes operations of the timer (low-speed timer/timer/high-speed timer).
Ex.
A subroutine-type FB using a low-speed timer
When "Yes" is selected for "Use MC/MCR to Control EN"
The count value becomes 0 ((1) in the following figure). The coil turns off ((2) in the following figure).
When "No" is selected for "Use MC/MCR to Control EN"
The current count value and the current state of the coil remain unchanged. ((1) in the following figure).
Sc: Scan
T0 (Count): T0 (count value)
T0 (Coil): T0 (coil)
EN is turned off. (User operation)
The coil turns off and the timer value and the count value are cleared. (CPU module operation)
Sc: Scan
T0 (Count): T0 (count value)
T0 (Coil): T0 (coil)
EN is turned off. (User operation)
The values remain unchanged. (CPU module operation)
SM400
ENO
EN
OUT T0 K3
END
T0 (Count)
EN
T0 (Coil)
(1)
(2)
Sc
012 2301
T0 (Count)
EN
T0 (Coil)
(1)
(1)
Sc
012 3333