66
7 FBD/LD LANGUAGE
7.1 Configuration
Common unit
This represents a common unit placed on the FBD/LD editor.
*1 These elements cannot be used in the Zoom editor of SFC programs.
Precautions for a jump unit
If the timer of a coil that is ON is jumped over by using a jump unit, a normal measurement cannot be conducted.
You can add a jump label on the top side (the execution is earlier) of a jump unit. In this case, create the program by
including a method to break the loop in order not to exceed the setting value of the watchdog timer.
You can specify only a local label of a pointer type for a jump element and jump label. The structure members cannot be
used.
The pointer branch instruction (CJ) cannot be used. For jumping, use jump elements.
Jumps to or from outside the program block cannot be executed. The following is a list of jump operations that cannot be
executed.
- Jumping to outside the program block
*1
- Jumping from outside the program block
*1
- Calling subroutine programs
- Called as subroutine programs
*1 Includes branches caused by the BREAK instruction.
Unit Symbol Description
Jump
*1
The execution processing is jumped over from a jump unit to a jump label. The portion that is
jumped over is not executed.
Whether a jump is made or not is controlled depending on the ON/OFF information to the jump unit.
ON: The execution processing is jumped over up to a jump label.
OFF: The execution processing is not jumped over but is executed.
Jump label
*1
This is the destination of a jump from a jump instruction in the same program. The processing is
executed from a program in the execution order after the jump label.
Connector This is used as a substitute of a connecting wire.
The processing moves on to the corresponding connector unit.
You can use one input connector or multiple input connectors for one output connector.
Return
*1
The processing after a return unit in the program is aborted. Use this when you want to prohibit the
execution of the processing of a program, function, or a function block after the return unit.
Whether the return processing is executed or not is controlled depending on the ON/OFF
information to the return unit.
ON: The return processing is executed.
OFF: The return processing is not executed, but the ordinary execution processing is executed.
Comment Use this to describe a comment.