4 SAFETY FB SPECIFICATIONS
4.11 M+SF_MUTEP_R
75
4
List of error codes
o_wDiagCode
(Hexadecimal)
State name Description, output setting Action
C001H Reset Error 1 Static i_bReset condition detected after FB activation in state
8001H.
Set i_bReset to OFF.
Check the devices and wiring related to
i_bReset.
C003H Error Muting Lamp Error detected in muting lamp. Set i_bReset to ON.
Check the devices and wiring related to
i_bReset.
CYx4H Error Muting Sequence Error detected in muting sequence in state 8000H, 8011H, 8311H,
8012H, 8021H, 8014H, 8314H, 8122H, 8422H, 8121H, 8112H,
8114H, or 8414H.
Y = Status in the sequence (6 states for forward and 6 states for
backward direction).
C0x4H = Error occurred in state 8000H
C1x4H = Error occurred in state Forward 8011H
C2x4H = Error occurred in state Forward 8311H
C3x4H = Error occurred in state Forward 8012H
C4x4H = Error occurred in state Forward 8014H
C5x4H = Error occurred in state Forward 8314H
C6x4H = Error occurred in state Forward 8021H
C7x4H = Error occurred in state Backward 8122H
C8x4H = Error occurred in state Backward 8422H
C9x4H = Error occurred in state Backward 8121H
Cax4H = Error occurred in state Backward 8114H
Cbx4H = Error occurred in state Backward 8414H
Ccx4H = Error occurred in state Backward 8112H
CFx4H = i_bMutingEnable=OFF
The states of wrong muting sequences ( Page 73 Wrong
muting sequences) including i_bMutingEnable=OFF are always
changed to CFx4H when i_bMutingEnable is set to OFF. (Never
changed to other states.)
x = Status of the sensors when error occurred
(MS_11, MS_12, MS_21, MS_22 in order)
CY04H=OFF, OFF, OFF, OFF
CY14H=ON, OFF, OFF, OFF
CY24H=OFF, ON, OFF, OFF
CY34H=ON, ON, OFF, OFF
CY44H=OFF, OFF, ON, OFF
CY54H=ON, OFF, ON, OFF
CY64H=OFF, ON, ON, OFF
CY74H=ON, ON, ON, OFF
CY84H=OFF, OFF, OFF, ON
CY94H=ON, OFF, OFF, ON
CYA4H=OFF, ON, OFF, ON
CYB4H=ON, ON, OFF, ON
CYC4H=OFF, OFF, ON, ON
CYD4H=ON, OFF, ON, ON
CYE4H=OFF, ON, ON, ON
CYF4H=ON, ON, ON, ON
Set all muting switches to OFF and set
i_bReset to ON.
Check the devices and wiring related to
i_bReset.
C004H to CFF4H
C005H Parameter Error i_dDiscTime11_12, i_dDiscTime21_22 or i_dMaxMutingTime
value out of range.
Set all values of i_dDiscTime11_12,
i_dDiscTime21_22, and
i_dMaxMutingTime within the setting
range, and set i_bReset to ON.
C006H Error Timer MaxMuting Timing error. Active muting time exceeds i_dMaxMutingTime. Set all muting switches to OFF and set
i_bReset to ON. Check the muting
situation in the process.
C007H Error Timer MS11_12 Timing error. Discrepancy time for switching i_bMutingSw_11 and
i_bMutingSw_12 > i_dDiscTime11_12.
C008H Error Timer MS21_22 Timing error. Discrepancy time for switching i_bMutingSw_21 and
i_bMutingSw_22 > i_dDiscTime21_22.