100
2 CONTROL MODE
2.3 Control mode [A]
Speed limit value selection
The speed limit can be selected with SP1 (Speed selection 1), SP2 (Speed selection 2), and SP3 (Speed selection 3).
*1 0: Off
1: On
When internal speed 1 to 7 are used to limit a speed, the speed does not vary with the ambient temperature.
VLC (Limiting speed)
VLC turns on when the servo motor speed reaches a speed limited with internal speed 1 to 7 or the analog speed limit.
Input device
*1
Speed limit
SP3 SP2 SP1
0 0 0 VLA (Analog speed limit)
0 0 1 [Pr. PC05 Internal speed 1]
0 1 0 [Pr. PC06 Internal speed 2]
0 1 1 [Pr. PC07 Internal speed 3]
1 0 0 [Pr. PC08 Internal speed 4]
1 0 1 [Pr. PC09 Internal speed 5]
1 1 0 [Pr. PC10 Internal speed 6]
1 1 1 [Pr. PC11 Internal speed 7]