204
4 APPLICABLE FUNCTIONS
*1 Available on servo amplifiers with firmware version A5 or later.
Function to shorten operating time
Performance-improving function
*1 Available on servo amplifiers with firmware version A5 or later.
A/B/Z-phase pulse output function Outputs the position information of the servo motor or the load-side
encoder as A/B/Z-phase pulses. Use this function to execute
synchronous control or other operations.
Page 351 A/B/Z-phase pulse output
function
Applicable function Outline Reference
Parameter automatic setting Transmits servo parameter data from the controller with SLMP
communication via CC-Link IE TSN.
Refer to "Parameter automatic setting" in the
User's Manual (Communication Function).
Software reset The same processing performed at power cycle of the servo amplifier
is performed without the need for actual cycling. Resets the status of
the servo amplifier.
Page 337 Software reset
Applicable function Outline Reference
Command offset
*1
This function adds an arbitrary offset amount for the position/speed/
torque commands.
Use this function to correct the target command or to improve the
response to the target command.
Page 377 Command offset [G]
Applicable function Outline Reference