■Temporary stop/restart/remaining distance clear
Transmitting the following command, data No., and data during positioning operation will decelerate the servo motor to a stop.
Transmitting the following command, data No., and data during a temporary stop will restart the servo motor.
*1 "_" indicates a blank.
Transmitting the following command, data No., and data during a temporary stop will stop positioning operation and erase the
remaining travel distance.
*1 "_" indicates a blank.
Command Data No. Data
[A] [0] [4] [1] STOP
Command Data No. Data
*1
[A] [0] [4] [1] GO _ _
Command Data No. Data
*1
[A] [0] [4] [1] CLR _