Do you have a question about the Mitsubishi Electric Mr. Slim MSH09NW and is the answer not in the manual?
Brand | Mitsubishi Electric |
---|---|
Model | Mr. Slim MSH09NW |
Category | Air Conditioner |
Language | English |
Features of the advanced remote controller with "I Feel Control" and timer.
How to select airflow direction and vane swing using the remote.
Highlights the compact design of the indoor unit.
Details the auto-restart function after power outages.
Describes the benefits of the rotary compressor.
Lists technical changes for MSH09EW/MSH09NW models.
Lists technical changes for MSH12NN/MSH15NN models.
Mentions the MSH17NN as a new model.
Identifies and labels parts of the remote controller.
Lists specifications for the indoor unit.
Lists specifications for the outdoor unit.
Specifies details of the remote controller.
Details refrigerant piping specifications.
Defines operational temperature and humidity ranges.
Presents detailed performance data including capacity and corrections.
Illustrates performance curves for cooling and heating across different conditions.
Shows condensing and suction pressure curves for various operating conditions.
Shows outline and dimensions for the MSH09NW indoor unit.
Shows outline and dimensions for the MUH09NW outdoor unit.
Shows outline and dimensions for MSH12NN/MSH15NN/MSH17NN indoor units.
Shows outline and dimensions for MUH12NN/MUH15NN outdoor units.
Shows outline and dimensions for the MUH17NN outdoor unit.
Wiring diagram for MSH09NW indoor unit.
Wiring diagram for MUH09NW outdoor unit.
Wiring diagrams for MSH12NN/MSH15NN/MSH17NN indoor units.
Wiring diagrams for MUH12NN/MUH15NN/MUH17NN outdoor units.
Illustrates refrigerant flow for MSH09NW/MUH09NW units.
Illustrates refrigerant flow for MSH12NN/MSH15NN/MUH12NN/MUH15NN units.
Illustrates refrigerant flow for MSH17NN/MUH17NN units.
Details the operation of the "I Feel Control" feature.
Explains operation procedures for Cool, Dry, and Heat modes.
Explains fan motor control and automatic vane operation.
Guides on timer functions and emergency/test operations.
Details relay operations and coil frost prevention modes.
Describes how to activate the compulsory defrosting mode for service.
Details how to change defrost termination conditions.
Explains the auto restart function and its memorization.
Describes how to shorten timer settings for service.
Lists important precautions to take before troubleshooting.
Provides a flowchart for diagnosing unit problems.
Lists troubleshooting symptoms, detection methods, and check points.
Lists criteria for checking main components for faults.
Guides for checking specific components like motors and boards.
Instructions for disassembling the MSH09NW indoor unit.
Instructions for disassembling MSH12NN/MSH15NN/MSH17NN indoor units.
Instructions for disassembling the MUH09NW outdoor unit.
Instructions for disassembling MUH12NN/MUH15NN outdoor units.
Instructions for disassembling the MUH17NN outdoor unit.
Lists structural parts for the MSH09NW indoor unit.
Lists heat exchanger parts for the MSH09NW indoor unit.
Lists electrical parts for the MSH09NW indoor unit.
Lists structural parts for the MUH09NW outdoor unit.
Lists functional and electrical parts for the MUH09NW outdoor unit.
Lists structural parts for MSH12NN/MSH15NN/MSH17NN indoor units.
Lists heat exchanger parts for MSH12NN/MSH15NN/MSH17NN indoor units.
Lists electrical parts for MSH12NN/MSH15NN/MSH17NN indoor units.
Lists structural parts for MUH12NN/MUH15NN outdoor units.
Lists structural parts for the MUH17NN outdoor unit.
Lists accessory and remote controller parts.
Details specifications for optional refrigerant extension pipes.
Describes the air cleaning filter, its maintenance, and replacement.
Describes the deodorizing filter, its cleaning, and replacement.