EasyManua.ls Logo

Mitsubishi Electric MS15EN User Manual

Mitsubishi Electric MS15EN
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE
&
PARTS
MANUAL
Wireless type
Models
INDOOR UNlT
MSOSEW
MS12EN
OUTDOOR UNlT
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MS15EN and is the answer not in the manual?

Mitsubishi Electric MS15EN Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMS15EN
CategoryAir Conditioner
LanguageEnglish

Summary

CHANGE POINTS

FEATURES

NEW "I FEEL CONTROL" IN OUR LCD WIRELESS REMOTE CONTROLLER

Introduces the new wireless remote controller with advanced features and 'I FEEL CONTROL'.

A VARIETY OF MICROPROCESSOR-CONTROLLED FUNCTION

Details various functions controlled by the microprocessor, including timers and fan speed.

SPECIFICATIONS

DATA

PERFORMANCE CURVE

Graphs showing cooling capacity and power consumption versus temperature.

CONDENSING PRESSURE AND SUCTION PRESSURE

OPERATING RANGE

POWER SUPPLY

Details the power supply specifications for indoor and outdoor units.

OPERATION

Defines operating conditions and temperatures for cooling.

OUTLET AIR SPEED AND COVERAGE RANGE

Provides airflow data and coverage range for different models.

ADDITIONAL REFRIGERANT CHARGE

Specifies refrigerant charge amounts for various piping lengths.

MAX. REFRIGERANT PIPING LENGTH & MAX. HEIGHT DIFFERENCE

STANDARD OPERATION DATA

OUTLINES AND DIMENSIONS

MS09EW Units

Dimensional drawings and required space for MS09EW indoor and outdoor units.

MS12EN/MS15EN Units

Dimensional drawings and required space for MS12/15EN indoor and outdoor units.

MUM18EW Outdoor Unit

Dimensional drawings and required space for MUM18EW outdoor unit.

WIRING DIAGRAM

REFRIGERANT SYSTEM DIAGRAM

MS09EW/MU09EW

Refrigerant system diagram for MS09EW indoor and MU09EW outdoor units.

MS12EN/MU12EN & MS15EN/MU15EN

Refrigerant system diagram for MS12/15EN indoor and MU12/15EN outdoor units.

MS09EW x 2/MUM18EW

Refrigerant system diagram for MS09EW x 2 and MUM18EW units.

MICROPROCESSOR CONTROL

Wireless Remote Controller

Details the functions and operation of the wireless remote controller.

"I FEEL CONTROL" Operation

Explains how to use the 'I FEEL CONTROL' feature for personalized comfort.

DRY Operation

Explains the operation and settings for DRY mode to reduce humidity.

COOL Operation

Describes the procedures and settings for COOL operation mode.

FAN Operation

Details how to operate the unit in FAN-only mode and fan speed selection.

Timer Functions

Covers AUTO STOP, AUTO START, and EMERGENCY-TEST timer functions.

SERVICE FUNCTION

AUTO RESTART FUNCTION

Explains the auto restart function after power failure.

Reconstruction for Individual Operation

Details how to reconstruct PC boards for individual unit operation.

TROUBLE SHOOTING

Self Check Function

Describes the self-check function for identifying unit defects.

Troubleshooting Flowcharts

Flowcharts to diagnose and resolve operational issues.

TEST POINT DIAGRAM AND VOLTAGE

OPTIONAL PARTS

REFRIGERANT PIPES

Details optional refrigerant pipe kits, lengths, and specifications.

STANDARD PARTS

MS09EW Indoor Unit Parts

Exploded view and parts list for MS09EW indoor unit.

MU09EW Outdoor Unit Parts

Exploded view and parts list for MU09EW outdoor unit.

MUM18EW Outdoor Unit Parts

Exploded view and parts list for MUM18EW outdoor unit.

MS12EN/MS15EN Indoor Unit Parts

Exploded view and parts list for MS12/15EN indoor units.

MS12EN/MU15EN Outdoor Unit Parts

Exploded view and parts list for MU12/15EN outdoor units.

Accessory & Remote Controller Parts

Parts list for accessories and remote controller components.

Related product manuals