C.1 WALL-MOUNTED ..................................................................................C-3
M series Model List
Outdoor unit
MU-GA20VB E3
MU-GA25VB E2
MU-GA35VB E3
MUH-GA20VB E2
MUH-GA25VB E3
MUH-GA35VB E3
MU-GE50VB E1
MU-GA60VB E1
MU-GD80VB E1
MUH-GE50VB E1
MUH-GA60VB E1
MUH-GD80VB E1
MUZ-FD25VA E1
MUZ-FD25VABH E1
MUZ-FD35VA E1
MUZ-FD35VABH E1
MUZ-FD50VA E1
MUZ-FD50VABH E1
MUZ-GE25VA E1
MUZ-GE25VAH E1
MUZ-GE35VA E1
MUZ-GE35VAH E1
MUZ-GE42VA E1
MUZ-GE42VAH E1
MUZ-GE50VA E1
MUZ-GE50VAH E1
MUZ-GE60VA E1
MUZ-GE71VA E1
MUZ-HC25VA E1
MUZ-HC35VA E2
MUZ-HC35VAB E2
Indoor unit
MSC-GE20VB E1
MSC-GE25VB E1
MSC-GE35VB E1
MS-GE50VB E1
MS-GA60VB E1
MS-GD80VB E1
MSH-GE50VB E1
MSH-GA60VB E1
MSH-GD80VB E1
MSZ-FD25VA E2
MSZ-FD25VAS E2
MSZ-FD35VA E2
MSZ-FD35VAS E2
MSZ-FD50VA E2
MSZ-FD50VAS E2
MSZ-GE22VA E1
MSZ-GE25VA E1
MSZ-GE35VA E1
MSZ-GE42VA E1
MSZ-GE50VA E1
MSZ-GE60VA E1
MSZ-GE71VA E1
MSZ-HC25VA E1
MSZ-HC35VA E2
MSZ-HC35VAB E2
MSZ-SF15VA E1
MSZ-SF20VA E1
Back to Index page

Table of Contents

Other manuals for Mitsubishi Electric MUH-GA60VB

Questions and Answers

  • R
    Roger WilliamsAug 15, 2025
    What to do if Mitsubishi Electric Air Conditioner is flashing 4 times?
    • M
      Melanie DownsAug 15, 2025
      If your Mitsubishi Electric Air Conditioner is flashing 4 times, it indicates a problem with the indoor unit control system. The suggested solution is to replace the indoor electronic control P.C. board.
  • L
    Lori BlackwellAug 18, 2025
    What does it mean when my Mitsubishi Electric MUH-GA60VB Air Conditioner flashes 2 times?
    • A
      Andrea PageAug 18, 2025
      If your Mitsubishi Electric Air Conditioner is flashing twice, it indicates a problem with the room temperature or indoor coil thermistor. Check the room temperature thermistor to resolve this issue.
  • J
    Jeremy CoxAug 21, 2025
    What does 7 flashes mean on a Mitsubishi Electric MUH-GA60VB?
    • D
      Denise TownsendAug 22, 2025
      If your Mitsubishi Electric Air Conditioner flashes 7 times, this indicates an issue with the outdoor control system. The suggested solution is to replace the deicer P.C. board.
  • A
    Adrian LoganAug 25, 2025
    What does it mean when Mitsubishi Electric MUH-GA60VB Air Conditioner flashes 6 times?
    • D
      Dr. Deanna DavisAug 26, 2025
      If your Mitsubishi Electric Air Conditioner is flashing 6 times, it indicates a problem with the thermistor. Refer to 10-4.F "Check of outdoor thermistor".
  • D
    Derek FrenchAug 28, 2025
    What does 10 flashes mean on my Mitsubishi Electric Air Conditioner?
    • L
      lisaarnoldAug 28, 2025
      If your Mitsubishi Electric Air Conditioner is flashing 10 times, it indicates a trouble of low discharge temperature protection. Refer to the indoor unit service manual.
  • S
    seth29Aug 31, 2025
    What to do if Mitsubishi Electric MUH-GA60VB Air Conditioner indoor unit only works with EMERGENCY OPERATION switch?
    • E
      Erin ReeseSep 1, 2025
      If the indoor unit of your Mitsubishi Electric Air Conditioner only operates when the EMERGENCY OPERATION switch is pressed, check the indoor/outdoor connecting wire. Refer to "Check of indoor electronic control P.C. board".
  • A
    Angela PetersonSep 4, 2025
    What to do if Mitsubishi Electric Air Conditioner indoor unit doesn't operate with EMERGENCY OPERATION switch?
    • C
      Christina McmahonSep 4, 2025
      If the indoor unit of your Mitsubishi Electric Air Conditioner doesn't operate even when the EMERGENCY OPERATION switch is pressed, check the indoor / outdoor connecting wire. Refer to "Check of indoor electronic control P.C. board".
  • A
    Amy CamposSep 7, 2025
    What does it mean when my Mitsubishi Electric MUH-GA60VB Air Conditioner flashes 3 times?
    • M
      mstewartSep 7, 2025
      If your Mitsubishi Electric Air Conditioner is flashing 3 times, it indicates a problem with the indoor fan motor. Refer to "Check of indoor fan motor".
  • R
    Rebecca CainSep 12, 2025
    Why my Mitsubishi Electric MUH-GA60VB Air Conditioner outdoor unit only operates in Test Run?
    • M
      Michelle DouglasSep 12, 2025
      If the outdoor unit of your Mitsubishi Electric Air Conditioner operates only in Test Run operation, check the room temperature thermistor. Refer to "Test point diagram and voltage".

Mitsubishi Electric MUH-GA60VB Specifications

General IconGeneral
Cooling Capacity6.0 kW
Power Supply220-240 V, 50 Hz
Indoor Unit Dimensions (W x H x D)1100 x 325 x 235 mm
Outdoor Unit Dimensions (W x H x D)840 x 880 x 330 mm
TypeSplit System