Category | Air Conditioner |
---|---|
Type | Multi-split |
Cooling Capacity (kW) | 3.3 |
Heating Capacity (kW) | 3.6 |
Energy Efficiency Ratio (EER) | 3.5 |
Seasonal Energy Efficiency Ratio (SEER) | 6.1 |
Seasonal Coefficient of Performance (SCOP) | 4.0 |
Energy Efficiency Class (Cooling) | A++ |
Energy Efficiency Class (Heating) | A+ |
Power Supply | 220-240 V, 50 Hz |
Refrigerant | R32 |
Sound Power Level (Cooling) dB(A) | 56 |
Maximum Number of Connectable Indoor Units | 2 |
Outdoor Unit Dimensions (WxHxD) | 800 x 550 x 285 mm |
Coefficient of Performance (COP) | 4.0 |
Indoor Unit Compatibility | MSZ-LN |
General safety rule emphasizing disconnecting power before accessing terminals.
Specific safety warnings and precautions for using R32 refrigerant.
Graphs detailing capacity and input correction factors based on operating conditions.
Graphs showing how capacity and input change with inverter output frequency.
Details the relationship between system sensors and their corresponding actuators.
Identifies the location and function of switches on the outdoor P.C. boards.
Describes how to lock the unit into a specific operating mode (COOL, DRY, or HEAT).
Instructions on how to activate or deactivate the low standby power mode.
Explains how to reduce the operating noise of the outdoor unit, potentially impacting capacity.
Details the function that automatically detects and corrects improper wiring or piping.
Instructions on how to adjust the refrigerant evaporating temperature setting.
Describes how to change the ampere limit for the outdoor unit's current.
Instructions for adjusting settings when the refrigerant piping length is extended.
Essential safety precautions and checks to perform before starting troubleshooting.
How to recall and interpret failure codes stored in the unit's memory.
A flowchart guiding the troubleshooting process based on LED indicators.
A detailed table correlating LED indications with abnormal points, conditions, and remedies.
Specifications for checking the resistance and voltage of key components.
Flowcharts for troubleshooting specific operational issues like outdoor unit not operating or incorrect wiring.
Diagrams showing test points and voltage readings on P.C. boards for diagnostics.
Step-by-step instructions for removing panels and cabinets of specific MXZ 2F series models.
Instructions for removing panels of specific MXZ 4F/5F series models.
Instructions for removing panels of specific MXZ 4F83VFHZ/VFHZ2 models.
Instructions for removing panels of specific MXZ 6F models.