EasyManua.ls Logo

Mitsubishi Electric MXZ-6F120VF2-E1 User Manual

Mitsubishi Electric MXZ-6F120VF2-E1
237 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HFC
utilized
R32
SERVICE MANUAL
No. OBH790
REVISED EDITION-L
OUTDOOR UNIT
PARTS CATALOG (OBB790)
Indoor unit service manual
MSZ-LN•VG Series (OBH766)
MSZ-LN•VG2 Series (OBH766)
MSZ-EF•VG Series (OBH589)
MSZ-AP•VF Series (OBH799)
MSZ-AP•VG Series (OBH788)
MSZ-BT•VG Series (OBH849)
MSZ-AY•VG Series (OBH930, 932)
MLZ-KP•VF Series (OBH801)
MFZ-KT•VG Series (OBH843)
MLZ-KY•VG Series (OBH921)
SLZ-M•FA Series (OCH522)
SEZ-M•DA Series (HWE17040)
CONTENTS
INDOOR / OUTDOOR UNIT
COMPATIBILITY TABLE ·······················4
1. TECHNICAL CHANGES ······························7
2. SAFETY PRECAUTION ·······························9
3. PART NAMES AND FUNCTIONS ················19
4. SPECIFICATION ······································21
5. NOISE CRITERIA CURVES ························58
6. OUTLINES AND DIMENSIONS ··················· 62
7. WIRING DIAGRAM ··································· 70
8. REFRIGERANT SYSTEM DIAGRAM ··········111
9. PERFORMANCE CURVES ······················· 122
10. ACTUATOR CONTROL ··························· 171
11. SERVICE FUNCTIONS ···························· 172
12. TROUBLESHOOTING ····························· 179
13. DISASSEMBLY INSTRUCTIONS ··············· 214
MXZ-2F33VF2
MXZ-2F42VF2
MXZ-2F53VF2
MXZ-2F53VFH2
MXZ-2F33VF3
MXZ-2F42VF3
MXZ-2F53VF3
MXZ-2F53VFH3
MXZ-2F33VF4
MXZ-2F42VF4
MXZ-2F53VF4
MXZ-2F53VFH4
OBH790 REVISED EDITION-K is void.
MXZ-2F33VF
MXZ-2F42VF
MXZ-2F53VF
MXZ-2F53VFH
Models
MXZ-2F33VF -
E1
,
ET1
MXZ-3F68VF -
E1
,
ET1
,
E2
,
ET2
MXZ-2F33VF2 -
E1
,
ET1
MXZ-3F68VF2 -
E1
,
ET1
MXZ-2F33VF3 -
E1
,
ET1
,
ER1
,
E2
MXZ-3F68VF3 -
E1
,
ET1
,
ER1
MXZ-2F33VF4 -
E1
,
ET1
MXZ-3F68VF4 -
E1
,
ET1
MXZ-2F42VF -
E1
,
ET1
MXZ-4F72VF -
E1
,
ET1
,
E2
,
ET2
MXZ-2F42VF2 -
E1
,
ET1
MXZ-4F72VF2 -
E1
,
ET1
MXZ-2F42VF3 -
E1
,
ET1
,
ER1
,
E2
MXZ-4F72VF3 -
E1
,
ET1
,
ER1
MXZ-2F42VF4 -
E1
,
ET1
MXZ-4F72VF4 -
E1
,
ET1
MXZ-2F53VF -
E1
,
ET1
MXZ-4F80VF2 -
E1
,
ET1
MXZ-2F53VF2 -
E1
,
ET1
MXZ-4F80VF3 -
E1
,
ET1
MXZ-2F53VF3 -
E1
,
ET1
,
ER1
,
E2
MXZ-4F80VF4 -
E1
,
ET1
MXZ-2F53VF4 -
E1
,
ET1
MXZ-4F83VF -
E1
,
ET1
,
ER1
MXZ-2F53VFH -
E1
MXZ-4F83VF2 -
E1
,
ET1
MXZ-2F53VFH2 -
E1
MXZ-5F102VF -
E1
,
ET1
,
ER1
MXZ-2F53VFH3 -
E1
,
E2
MXZ-5F102VF2 -
E1
,
ET1
MXZ-2F53VFH4 -
E1
MXZ-6F120VF2 -
E1
,
ET1
MXZ-3F54VF -
E1
,
ET1
,
E2
,
ET2
MXZ-6F122VF -
E1
,
ET1
,
ER1
MXZ-3F54VF2 -
E1
,
ET1
MXZ-2F53VFHZ -
E1
,
ER1
MXZ-3F54VF3 -
E1
,
ET1
,
ER1
,
E2
,
ET2
,
ER2
MXZ-2F53VFHZ2 -
E1
MXZ-3F54VF4 -
E1
,
ET1
MXZ-4F83VFHZ -
E1
,
ER1
MXZ-4F83VFHZ2 -
E1
Revision L:
• MXZ-2F33/42/53VF4 -
E1
,
ET1
,
MXZ-2F53VFH4 -
E1
, MXZ-3F54/68VF4 -
E1
,
ET1
,
MXZ-4F72/80VF4 -
E1
,
ET1
, MXZ-4F83VF2 -
E1
,
ET1
,
MXZ-5F102VF2 -
E1
,
ET1
, MXZ-6F120VF2 -
E1
,
ET1
,
MXZ-2F53VFHZ2 -
E1
and MXZ-4F83VFHZ2 -
E1
have been added.
SFZ-M•VA Series (HWE19090)
PCA-M•KA Series (OCH659)
PEAD-M•JA(L) Series (HWE16130)
PEAD-M•JA(L)2 Series (HWE21070)
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MXZ-6F120VF2-E1 and is the answer not in the manual?

Mitsubishi Electric MXZ-6F120VF2-E1 Specifications

General IconGeneral
SeriesMXZ
RefrigerantR410A
Indoor Units SupportedUp to 6
HSPF10.0
PhaseSingle
Indoor Unit WeightVaries by model
Operating Temperature Range (Cooling)14°F to 115°F
Operating Temperature Range (Heating)-13°F to 75°F
Indoor Unit Noise LevelData varies depending on the connected indoor unit model.
Indoor Unit Dimensions (HxWxD)Varies by model
TypeMulti-Split System
Power Supply208/230V, 60Hz
Sound Level (dB)56

Summary

Service Manual

Contents

Table of contents listing all major sections and their starting pages.

Indoor/Outdoor Unit Compatibility Table

Safety Precautions

Always Observe for Safety

General safety guidelines to follow before accessing electrical circuits and performing maintenance.

Cautions Related to New Refrigerant

Specific safety precautions for handling R32 refrigerant during repair services.

Specifications

Wiring Diagram

Refrigerant System Diagram

Service Functions

Automatic Line Correcting

Function to automatically detect and correct improper indoor/outdoor wiring or piping connections.

Troubleshooting

Cautions on Troubleshooting

Important safety and procedural checks before starting troubleshooting steps.

Outdoor Unit Failure Mode Recall Function Table

Detailed table of symptoms, LED indications, abnormal points, conditions, and remedies.

Disassembly Instructions

Related product manuals