4.5Connectinginputs/outputs
For multiple outdoor units control with FTC (Slave), see section 9.
FTC (Master)
1 2
3
4
5
6
+ - + - + -
Analog input
(0.5 - 3.5V)
5VDC
GND
12
13
14
TBI.3
IN10IN9IN8 IN1A
1
3
CN3C
(BLU)
1
3
CNPWM
(WHT)
LED1
LED2
LED3
LED4
CN108
5
1
5
1
5
1
CNRF
(WHT)
CN105
(RED)
TBO.1
TBO.2
TBO.3
TBO.4
CNP1
(WHT)
CNP4
(RED)
CNV1
(WHT)
CNIT
(BLU)
CN01
(WHT)
F2 F1
6.3A 250V 10A 250V
SW1
SW2
SW3
SW4
SW5
1
8
1
8
1
1
5
1
3
1
3
8
1
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
7
8
TBO.5
1
2
3
4
5
6
7
8
1
2
3
4
5
6
8
1
6
1
2
4
6
1
2
1
2
CNBHT
(BLK)
1
3
1
3
CNIH
(ORN)
1
4
1
3
CNW5
(WHT)
CN21
(YLW)
CNW12
(RED)
CN20
(RED)
TBI.2
126 10
14
8
137 119
4
53
2
1
TBI.3
2 4 6 8 1012 14
1
3
5
7 9
11
13
1
4
CN1A
(WHT)
2 4 6 8 10 1214
1
3
5
7 9
11
13
TBI.1
4. Electrical work
When the wires are wired to adjacent terminals
use ring terminals and insulate the wires.
Signal inputs
Item Name Modelandspecications
Signal input
function
Signal input
wire
Use sheathed vinyl coated cord or cable.
Max. 30 m
Wire type: CV, CVS or equivalent
Wire size: Stranded wire 0.13 mm² to 1.25 mm²
Solid wire: ø0.4 mm to ø1.2 mm
Switch Non-voltage “a” contact signals
Remote switch: minimum applicable load 12V DC, 1mA
Wiringspecicationandlocalsupplyparts
Name Terminal block Connector Item OFF (Open) ON (Short)
IN1 TBI.1 13-14 Room thermostat 1 input *1 Refer to SW2-1 in <5.1 DIP Switch Functions>.
IN2 TBI.1 11-12 Flow switch 1 input Refer to SW2-2 in <5.1 DIP Switch Functions>.
IN3 TBI.1 9-10 Flow switch 2 input (Zone1) Refer to SW3-2 in <5.1 DIP Switch Functions>.
IN4 TBI.1 7-8 Demand control input Normal Heat source OFF/ Boiler operation *3
IN5 TBI.1 5-6 Outdoor thermostat input *2 Standard operation Heater operation/ Boiler operation *3
IN6 TBI.1 3-4 Room thermostat 2 input *1 Refer to SW3-1 in <5.1 DIP Switch Functions>.
IN7 TBI.1 1-2 Flow switch 3 input (Zone2) Refer to SW3-3 in <5.1 DIP Switch Functions>.
IN8 TBI.3 1-2 Electric energy meter 1
*4IN9 TBI.3 3-4 Electric energy meter 2
IN10 TBI.3 5-6 Heat meter
IN11 TBI.3 7-8
Smart grid ready input *5
IN12 TBI.3 9-10
IN1A TBI.3 12-14 CN1A Flow sensor input *6
*1. Set the ON/OFF cycle time of the room thermostat for 10 minutes or more; otherwise the compressor may be damaged.
*2. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts may be reduced.
*3. To turn on the boiler operation, use the main remote controller to select “Boiler” in “External input setting“ screen in the service menu.
*4. Connectable electric energy meter and heat meter
● Pulse type Voltage free contact for 12VDC detection by FTC (TBI.3 1, 3 and 5 pin have a positive voltage.)
● Pulse duration Minimum ON time: 40ms
Minimum OFF time: 100ms
● Possible unit of pulse 0.1 pulse/kWh 1 pulse/kWh 10 pulse/kWh
100 pulse/kWh 1000 pulse/kWh
Those values can be set by the main remote controller. (Refer to the menu tree in "7.2 Main remote controller".)
*5. As for the smart grid ready, refer to "4.9 Smart grid ready".
*6. Connectable ow sensor
● Power supply 5V DC
● Measuring range 5 to 100 L/min
Those values can be set by the main remote controller. (Refer to <Auxiliary setting> on Page 44.)
● Flow signal 0.5V (at minimum ow rate) to 3.5V (at maximum ow rate)
<Fig. 4.5.1>