SERVICE MANUAL
This manual describes only
service data of the indoor
units.
[Model names]
PEA-RP200GAQ
PEA-RP250GAQ
PEA-RP400GAQ
PEA-RP500GAQ
CONTENTS
1.
TYPES OF CONNECTED OUTDOOR UNITS
····2
2. SAFETY PRECAUTION ···································3
3. PART NAMES AND FUNCTIONS····················8
4. SPECIFICATIONS ··········································10
5. DATA ·······························································11
6. OUTLINES AND DIMENSIONS ·····················13
7. WIRING DIAGRAM ·········································16
8. REFRIGERANT SYSTEM DIAGRAM ············18
9. TROUBLESHOOTING ····································19
10. SERVICE DATA (PARTS NAME) ···················30
Indoor unit
Remote controller (option)
SPLIT-TYPE, HEAT PUMP
AIR CONDITIONERS
2010

Other manuals for Mitsubishi Electric PEA-RP500GAQ

Questions and Answers:

Mitsubishi Electric PEA-RP500GAQ Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPEA-RP500GAQ
CategoryAir Conditioner
LanguageEnglish

Summary

2 SAFETY PRECAUTION

[1] Cautions for service

Outlines essential service precautions, including refrigerant handling and environmental safety during maintenance.

[3] Brazing

[4] Airtightness Test

[5] Vacuuming

[6] Additional refrigerant charge

3 PART NAMES AND FUNCTIONS

6 OUTLINES AND DIMENSIONS

7 WIRING DIAGRAM

8 REFRIGERANT SYSTEM DIAGRAM

9 TROUBLESHOOTING

9-1. TROUBLESHOOTING Summary

Provides a summary of self-diagnosis error codes and general actions to take for troubleshooting recurring or non-recurring phenomena.

9-2. SELF-DIAGNOSIS ACTION TABLE

Details error codes P1, P2, P4, and P5, including their meaning, cause, and recommended countermeasures.

P6 Freezing/Overheating Protection

Describes error code P6 indicating freezing or overheating protection activation, detailing causes and countermeasures.

P8 Pipe Temperature Abnormality

Covers error code P8 for pipe temperature abnormalities during cooling or heating, listing potential causes and checks.

P9 Pipe Temperature Thermistor Abnormality

Details error code P9 regarding pipe temperature thermistor issues, including detection, causes, and countermeasures.

E0/E4 Remote Controller Communication Error

Explains error codes E0 and E4 indicating communication errors between remote controller and indoor unit, covering signal issues.

E3/E5 Remote Controller Communication Error

Addresses error codes E3 and E5 related to remote controller transmission errors and signal reception, including mis-wiring and noise.

E6 Communication Error (Signal Receiving)

Describes error code E6 for indoor/outdoor unit communication failures related to signal reception, including wiring and noise issues.

E7 Communication Error (Transmitting)

Explains error code E7 for indoor/outdoor unit communication errors concerning signal transmitting, potential causes and remedies.