SERVICE MANUAL
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS
NOTE:
• This manual describes
only service data of the
indoor units.
• RoHS compliant prod-
ucts have <G> mark on
the spec name plate.
CONTENTS
1. REFERENCE MANUAL
...................................
2
2. SAFETY PRECAUTION
...................................
3
3. PART NAMES AND FUNCTIONS
...................
4
4. SPECIFICATIONS
...........................................
12
5. NOISE CRITERION CURVES
.........................
14
6. OUTLINES AND DIMENSIONS
......................
16
7. WIRING DIAGRAM
.........................................
17
8. REFRIGERANT SYSTEM DIAGRAM
............
18
9. TROUBLESHOOTING
....................................
19
10. SPECIAL FUNCTION
.....................................
35
11. DISASSEMBLY PROCEDURE
.......................
45
Indoor unit
[Model names] [Service Ref.]
INDOOR UNIT
Model name
indication
PARTS CATALOG (OCB535)
No. OCH535
November 2012
PLA-ZRP35BA
PLA-ZRP50BA
PLA-ZRP60BA
PLA-ZRP71BA
PLA-ZRP125BA
PLA-ZRP140BA
PLA-ZRP35BA.UK
PLA-ZRP50BA.UK
PLA-ZRP60BA.UK
PLA-ZRP71BA.UK
PLA-ZRP125BA.UK
PLA-ZRP140BA.UK
WIRED REMOTE
CONTROLLER
WIRELESS REMOTE
CONTROLLER
ON/OFF TEMP
ON/OFF
TEMP.

Questions and Answers

  • S
    Stephanie MaciasJul 28, 2025
    What to do if the trouble is reoccurring on my Mitsubishi Electric PLA Air Conditioner?
    • H
      henry48Jul 28, 2025
      If the trouble with your Mitsubishi Electric Air Conditioner is reoccurring, determine what is wrong and take corrective action according to the self-diagnosis action table. Also, conduct troubleshooting to ascertain the cause of the problem.
  • B
    Brooke BuckleyAug 7, 2025
    What to do if the trouble is not reoccurring on my Mitsubishi Electric PLA Air Conditioner?
    • C
      Cindy SuttonAug 7, 2025
      If the trouble with your Mitsubishi Electric Air Conditioner is not reoccurring, consider that temporary defects may be the cause, such as the activation of protection devices in the refrigerant circuit (including the compressor), poor wiring connections, or noise. Re-check the symptom, and check the installation environment, refrigerant amount, weather when the trouble occurred, matters related to wiring, etc. Also, reset check code logs and restart the unit after finishing service. If there is no abnormality in electrical component, controller board, remote controller, etc., there is no problem.
  • P
    powersdanielAug 17, 2025
    What to do if the trouble is not logged on my Mitsubishi Electric PLA Air Conditioner?
    • E
      Elizabeth EllisAug 17, 2025
      If the trouble is not logged on your Mitsubishi Electric Air Conditioner, re-check the abnormal symptom. Conduct troubleshooting to ascertain the cause of the trouble. If the cause is not ascertained, continue to operate unit for the time being. Also, check that there is no abnormality concerning parts such as electrical components, the controller board, or the remote controller.

Summary

Safety Precaution

Always Observe for Safety

Essential safety rules to follow before servicing.

Cautions Related to New Refrigerant

Precautions for handling R410A refrigerant and related tools.

Part Names and Functions

Indoor Unit

Identifies parts of the indoor unit and their functions.

Troubleshooting

Troubleshooting

General approach to troubleshooting and error code summary.

Malfunction-Diagnosis Method by Remote Controller

Procedure for diagnosing malfunctions using the remote controller.

Self-Diagnosis Action Table

Table detailing error codes, causes, and countermeasures.

Disassembly Procedure

Mitsubishi Electric PLA Series Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPLA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals