EasyManua.ls Logo

Mitsubishi Electric PUHY-HP120TNU-A User Manual

Mitsubishi Electric PUHY-HP120TNU-A
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric PUHY-HP120TNU-A and is the answer not in the manual?

Mitsubishi Electric PUHY-HP120TNU-A Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPUHY-HP120TNU-A
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

General Precautions

General safety guidelines for installation and handling of air conditioners.

Check Before Servicing

Handling and Characteristics of Piping Materials, Refrigerant, and Refrigerant Oil

Working with Refrigerant Piping

1-3-4 Refrigerant Charging

Guidelines for charging refrigerant in the liquid phase for R410A systems.

Precautions for Wiring

Demand Control Overview

Restrictions on Refrigerant Pipes

Major Components, Their Functions and Refrigerant Circuits

Outdoor Unit Refrigerant Circuit Diagrams

Functions of the Major Components of Outdoor Unit

Functions of the Major Components of Indoor Unit

Electrical Components and Wiring Diagrams

Outdoor Unit Circuit Board Components

Outdoor Unit Electrical Wiring Diagrams

4-3 Outdoor Unit Electrical Wiring Diagrams

Detailed electrical wiring diagram for the YNU model, including component explanations.

Control

5-1 Dipswitch Functions and Factory Settings

Explains the functions and factory settings of dipswitches on outdoor and indoor units.

Outdoor Unit Switch Functions and Factory Settings

Indoor Unit Switch Functions and Factory Settings

Remote Controller Switch Functions and Factory Settings

Outdoor Unit Control

5-2-5 Refrigerant Bypass Control

Control logic for bypass solenoid valves (SV1a, SV2, SV9, SV10).

5-2-7 Defrost Operation Control

Conditions and procedures for starting and stopping the defrost operation.

5-2-9 Refrigerant Recovery Control

Procedures for recovering refrigerant during heating and cooling operations.

5-2-10 Outdoor Unit Fan Control

Control method for outdoor unit fan speed based on capacity requirements.

5-2-15 Control at Initial Startup

Process for initial startup mode and subsequent normal control.

Test Run

6-1 Read before Test Run

Essential checks and precautions before performing the test run of the unit.

Evaluating and Adjusting Refrigerant Charge

6-3-4 Refrigerant Charge Adjustment Mode

Procedures for adjusting refrigerant charge using the unit's adjustment mode and diagnostic switches.

Troubleshooting Using Error Codes

7-1 Error Code and Preliminary Error Code Lists

Comprehensive list of error codes, preliminary error codes, and their corresponding searched units.

7-2 Error Code Definitions and Solutions: Codes [0 - 999]

Detailed definitions and solutions for error codes in the 0-999 range.

7-3 Error Code Definitions and Solutions: Codes [1000 - 1999]

Detailed definitions and solutions for error codes in the 1000-1999 range.

7-4 Error Code Definitions and Solutions: Codes [2000 - 2999]

Detailed definitions and solutions for error codes in the 2000-2999 range.

7-5 Error Code Definitions and Solutions: Codes [3000 - 3999]

Detailed definitions and solutions for error codes in the 3000-3999 range.

7-6 Error Codes Definitions and Solutions: Codes [4000 - 4999]

Detailed definitions and solutions for error codes in the 4000-4999 range.

7-7 Error Code Definitions and Solutions: Codes [5000 - 5999]

Detailed definitions and solutions for error codes in the 5000-5999 range.

7-8 Error Code Definitions and Solutions: Codes [6000 - 6999]

Detailed definitions and solutions for error codes in the 6000-6999 range.

7-9 Error Code Definitions and Solutions: Codes [7000 - 7999]

Detailed definitions and solutions for error codes in the 7000-7999 range.

Troubleshooting Based on Observed Symptoms

8-3 Refrigerant Control Problems

Common issues related to refrigerant control and their solutions.

8-5 Pressure Sensor Circuit Configuration and Troubleshooting Pressure Sensor Problems

Explains the circuit configuration and troubleshooting steps for high-pressure sensors.

8-6 Troubleshooting Solenoid Valve Problems

Steps to check solenoid valve operations against control board signals and LED indicators.

8-7 Troubleshooting Outdoor Unit Fan Problems

Methods to check fan motor revolution and diagnose fan board or motor issues.

8-8 Troubleshooting LEV Problems

General overview of LEV operation and common problems with solutions.

8-9 Troubleshooting Inverter Problems

Common problems related to the inverter system and their solutions.

8-11 Measures for Refrigerant Leakage

Procedures for identifying and repairing refrigerant leaks.

8-12 Parts Replacement Instructions

Step-by-step instructions for replacing various parts of the unit.

8-13 Troubleshooting Problems Using the LED Status Indicators on the Outdoor Unit

Guide to troubleshooting issues using the LED status indicators on the outdoor unit circuit board.

USB Function

9-4 Maintenance LED Display and Troubleshooting

Information on understanding maintenance LED displays and troubleshooting related issues.

9-4-2 Troubleshooting

Troubleshooting steps for USB functions based on maintenance LED displays.

LED Status Indicators on the Outdoor Unit Circuit Board

Related product manuals