86
3 PROGRAMMING
3.1 Precautions for Programming
Transient transmission program
For a transient transmission program, configure an interlock with the following module labels.
"Baton pass status of own station" (SB0047)
"Baton pass status of each station" (SW00A0 to SW00A7)
Program example
Interlock example
Program using safety communication function
For a program using safety communication function, configure an interlock with the safety special register described below.
(For the 1st master/local module)
"Safety refresh communication status of each safety connection (1st module)" (SA\SD1008 to SA\SD1015)
For a communication example using the safety communication function, refer to the following.
(Page 87 Communication Example of Safety Communication Function)
Classification Label name Description Device
Module label RD77GF_1.stGF11.bSts_BatonPassError Baton pass status of own station SB0047
RD77GF_1.stGF11.bnSts_BatonPassError_Station[1] Baton pass status of each station (station No.1) SW00A0.0
(5) Module FB for the station No.1