1 FUNCTIONS
1.3 Cyclic Transmission
23
1
Direct access to link devices
This function directly accesses the link devices (RX, RY, RWr, RWw, SB, or SW) of the Simple Motion module from the
program. Specify a link device as the link direct device (J_\_) for direct access.
Specification method
Specify the network No. and the link device of the Simple Motion module for reading or writing.
Ex.
(1) Network No.: 1 to 239
(2) Remote input (RX): X0 to X3FFF
Remote output (RY): Y0 to Y3FFF
Remote register (RWw): W0 to W1FFF
Remote register (RWr): W2000 to W3FFF
Link special relay (SB): SB0 to SB1FF
Link special register (SW): SW0 to SW1FF
J
(1) (2)
__
\
RWw100 RWw100
RWr100 RWr100
RY1000
RY1000
RX1100RX1100
XY
W
RX
RWr RWw
RY RX RY
RWr RWw
Master station Slave station
Network No.1
Simple Motion
module
Send
request
CPU module Slave station
Cyclic transmission
MOV K20 J1\W100
= J1\W2100 K300
J1\X1100
J1\Y1000
Actual I/O