TECHNICAL & SERVICE MANUAL
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS
CONTENTS
1. TECHNICAL CHANGES ···········································2
2. COMBINATION OF INDOOR OUTDOOR UNITS·····2
3. PART NAMES AND FUNCTIONS·····························3
4. SPECIFICATIONS ·····················································4
5. DATA··········································································7
6. OUTLINES AND DIMENSIONS ······························10
7. WIRING DIAGRAM ·················································13
8.
REFRIGERANT SYSTEM DIAGRAM
···························19
9. TROUBLESHOOTING ············································28
10. DISASSEMBLY PROCEDURE ·······························32
11. PARTS LIST ····························································48
No. OC282
REVISED EDITION-B
OUTDOOR UNIT
Outdoor unit
[Model names] [Service Ref.]
SUH-1VR SUH-1VR.TH
SUH-1.6VR SUH-1.6VR.TH
SUH-1.6VR2 SUH-1.6VR2.TH
SUH-2VR SUH-2VR.TH SUH-2VR
1
.TH SUH-2VR
2
.TH
SUH-2.5VR SUH-2.5VR.TH
SU-1.6NR SU-1.6NR.TH
SU-2NR SU-2NR.TH
SU-2.5NR SU-2.5NR.TH
SU-1VR SU-1VR.TH SU-1VR.TH-T
SU-1.6VR SU-1.6VR.TH SU-1.6VR.TH-T
SU-1.6VR2 SU-1.6VR2.TH SU-1.6VR2.TH-T
SU-2VR SU-2VR.TH SU-2VR.TH-T
SU-2VR
1
.TH SU-2VR
1
.TH-T
SU-2.5VR SU-2.5VR.TH SU-2.5VR.TH-T
• SU-1VR.TH-T, SU-1.6VR2.TH-T and SU-2VR1.TH-T
has been added.
• Instruction of troubleshooting has been added to
pege 29 ans 30.
• Please void OC282 REVISED EDITION-A.
OC282-A--1.qxp 03.1.28 4:29 PM Page 1
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric SUH-1.6VR and is the answer not in the manual?

Mitsubishi Electric SUH-1.6VR Specifications

General IconGeneral
Cooling Capacity1.6 kW
Heating Capacity2.0 kW
Power Supply220-240 V, 50 Hz
Energy Efficiency Ratio (Cooling)3.5
Energy Efficiency Ratio (Heating)3.8
RefrigerantR410A
Indoor Unit Weight9 kg
TypeSplit Air Conditioner

Summary

Technical Changes

Specifications

Outlines and Dimensions

Wiring Diagram

Electrical Wiring Schematics and Component Symbols

Illustrates electrical connections and component layouts, including a symbol key.

Refrigerant System Diagram

Evacuation Procedures

Refrigerant System Evacuation Process

Outlines the step-by-step procedure for evacuating the refrigerant system.

Troubleshooting

P.C. Board Test Points and Defrost Thermistor Check

Identifies test points and provides checks for the deicer P.C. board and defrost thermistor.

Main Part Trouble Criteria

Provides resistance and condition criteria for diagnosing compressor and fan motor issues.