EasyManua.ls Logo

Mitsubishi Electric SUZ-KA35VA User Manual

Mitsubishi Electric SUZ-KA35VA
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
600o600
CEILING
CASSETTE
CEILING
CONCEALED
OUTDOOR
UNIT
B.1 600 o 600 CEILING CASETTE (SLZ) ....................................................B-3
Combination Table .........................................................................................B-2
SLZ-KA25VA
SLZ-KA25VAL
SLZ-KA35VA
SLZ-KA35VAL
SLZ-KA50VA
SLZ-KA50VAL
B.2 CEILING CONCEALED (SEZ) ................................................................B-39
SEZ-KD25VA
SEZ-KD25VAL
SEZ-KD35VA
SEZ-KD35VAL
SEZ-KD50VA
SEZ-KD50VAL
SEZ-KD60VA
SEZ-KD60VAL
SEZ-KD71VA
SEZ-KD71VAL
B.3 OUTDOOR UNIT (SUZ)..........................................................................B-85
SUZ-KA25VA
SUZ-KA35VA
SUZ-KA50VA
SUZ-KA60VA
SUZ-KA71VA
S series Model List

Other manuals for Mitsubishi Electric SUZ-KA35VA

Questions and Answers:

Mitsubishi Electric SUZ-KA35VA Specifications

General IconGeneral
CategoryAir Conditioner
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
RefrigerantR32
Power Supply220-240V, 50Hz
Seasonal Energy Efficiency Ratio (SEER)6.1
Indoor Unit Dimensions (W x H x D)800 x 290 x 230 mm
Outdoor Unit Dimensions (W x H x D)800 x 600 x 300 mm
Weight (Indoor Unit)9 kg
Noise Level (Outdoor)51 dB(A)

Summary

B.1 600 x 600 CEILING CASSETTE (SLZ)

B.1.1 SPECIFICATIONS

Detailed technical specifications for the ceiling cassette units.

B.1.2 OUTLINES AND DIMENSIONS

Physical dimensions and outlines of the indoor unit and remote controllers.

B.1.3 WIRING DIAGRAM

Electrical wiring diagrams for the SLZ series indoor units.

B.1.4 REFRIGERANT SYSTEM DIAGRAM

Diagram illustrating the refrigerant flow and components.

B.1.5 PERFORMANCE DATA

Cooling and heating performance data tables for various conditions.

B.1.6 4-WAY AIR FLOW SYSTEM

Information on fresh air intake and static pressure characteristics.

B.1.7 NOISE CRITERIA CURVES

Sound pressure level curves for different models and conditions.

B.1.8 OUTLET AIR SPEED AND COVERAGE RANGE

Data on airflow speed and coverage range of the unit.

B.1.9 CENTER OF GRAVITY POSITION

Coordinates for the center of gravity for installation purposes.

B.1.10 REMOTE CONTROLLER

Explanation of wireless and wired remote controller functions and buttons.

B.1.11 TROUBLESHOOTING

Guidance on identifying and resolving common issues and error codes.

B.1.12 INSTALLATION PROCEDURE

Step-by-step instructions for installing the indoor unit and related components.

B.2 CEILING CONCEALED (SEZ)

B.2.1 SPECIFICATIONS

Detailed technical specifications for the SEZ series ceiling concealed units.

B.2.2 OUTLINES AND DIMENSIONS

Physical dimensions and outlines of the SEZ indoor unit and remote controllers.

B.2.3 WIRING DIAGRAM

Electrical wiring diagrams for the SEZ series indoor units.

B.2.4 REFRIGERANT SYSTEM DIAGRAM

Diagram illustrating the refrigerant flow and components.

B.2.5 PERFORMANCE DATA

Cooling and heating performance data tables for various conditions.

B.2.6 NOISE CRITERIA CURVES

Sound pressure level curves for SEZ models at different static pressures.

B.2.7 INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW

Graphs showing indoor fan performance characteristics.

B.2.8 CENTER OF GRAVITY POSITION

Coordinates for the center of gravity for SEZ indoor units.

B.2.9 REMOTE CONTROLLER

Explanation of wired and wireless remote controller functions for SEZ units.

B.2.10 TROUBLESHOOTING

Guidance on identifying and resolving SEZ unit issues and error codes.

B.2.11 INSTALLATION PROCEDURE

Step-by-step instructions for installing SEZ indoor units and related components.

B.3 OUTDOOR UNIT (SUZ)

B.3.1 OUTLINES AND DIMENSIONS

Physical dimensions and required installation space for outdoor units.

B.3.2 WIRING DIAGRAM

Electrical wiring diagrams for the SUZ outdoor units.

B.3.3 REFRIGERANT SYSTEM DIAGRAM

Diagram illustrating the refrigerant flow and components for outdoor units.

B.3.4 PERFORMANCE CURVES

Graphs showing capacity and input correction factors based on conditions.

B.3.5 NOISE CRITERIA CURVES

Sound pressure level curves for outdoor units at different fan speeds.

B.3.6 ACTUATOR CONTROL

Explains the function of sensors and actuators in relation to the compressor and fan.

B.3.7 TROUBLESHOOTING

Guidance on troubleshooting common issues with outdoor units.

B.3.8 EARTHQUAKE-PROOF STRENGTH ANALYSIS

Calculation and verification of anchor bolt strength for seismic resistance.

B.3.9 CAPACITY CORRECTION RATIO CURVE PIPING LENGTH

Curves showing capacity correction based on refrigerant piping length.

B.3.10 INSTALLATION PROCEDURE

Step-by-step instructions for installing the outdoor unit.