EasyManua.ls Logo

Mitsubishi Heavy Industries SCM71ZM-S1 - 3. PIPING SYSTEM

Mitsubishi Heavy Industries SCM71ZM-S1
379 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-
121
-
'17 • SCM-T-225
Gas line
Liquid line
(
ȭ
9.52 or
ȭ
12.7)
(
ȭ
9.52 or
ȭ
12.7)
(
ȭ
6.35)
(
ȭ
6.35)
(
ȭ
6.35)
(
ȭ
6.35)
(
ȭ
9.52 or
ȭ
12.7)
(
ȭ
9.52 or
ȭ
12.7)
Service valve (Gas)
Outdoor unit
Indoor unit
Heat
exchanger
Sensor
(Th2
1
)
Sensor
(Th1)
Sensor
EEVA
EEVD
EEVC
EEVB
Strainer
Discharge
Suction
Sensor
(Tho-D)
Receiver
Sensor
(Tho-S)
Service valve
(Liquid)
Electronic
expansion valve
Compressor
Oil
separator
4way valve
Sensor
Heat exchanger
(Tho-A)
Sensor
(Tho-R)
Capillary tube
Capillary
tube
Accumulator
Accumulator
Cooling cycle
Heating cycle
(Th2
2
)
Humidity
sensor
2
1
1
1
1
(Th3)
2 Humidity sensor
SRK20, 25, 35, 50, 60ZSX-S, SRK35, 50ZS-S and SRF series only.
1 Gas line
Model 20, 25, 35 :
ȭ9.52
Model 50, 60 :
ȭ
12.7
3. PIPING SYSTEM
Models SCM71ZM-S1, 80ZM-S1