Why do I hear a slight cracking sound from my Mitsubishi Heavy Industries Air Conditioner?
- MMr. Martin BonillaSep 14, 2025
This is caused by heat expansion or contraction.
Why do I hear a slight cracking sound from my Mitsubishi Heavy Industries Air Conditioner?
This is caused by heat expansion or contraction.
Why Mitsubishi Heavy Industries Air Conditioner does not restart after power cut?
If the auto restart function is not set, the Mitsubishi Heavy Industries Air Conditioner will not restart automatically after a power cut, even if power has been restored. Use the remote control to start the operation again.
Why is my Mitsubishi Heavy Industries SRK71ZM-S Air Conditioner not cooling or heating well?
There might be a few reasons why your Mitsubishi Heavy Industries Air Conditioner isn't cooling or heating effectively. Here are a few things to check: * Make sure you've set the thermostat to a suitable temperature. * Check if the air filter is clean and not clogged. * Ensure that all doors and windows are closed.
What to do if my Mitsubishi Heavy Industries SRK71ZM-S does not work at all?
If your Mitsubishi Heavy Industries Air Conditioner isn't working, check these possible causes: * Ensure the power switch is turned on. * Check if the timer has been set to the “ON” position. * Verify there isn't a power failure or a blown fuse.
Why is my Mitsubishi Heavy Industries SRK71ZM-S Air Conditioner not cooling or heating properly?
There are several possible causes for poor cooling or heating in your Mitsubishi Heavy Industries Air Conditioner: * Check if you have set the thermostat at a suitable temperature. * Ensure the air filter is clean and not clogged. * Make sure you haven't left any doors or windows open.
Why does some steam escape during COOL operation of Mitsubishi Heavy Industries SRK71ZM-S Air Conditioner?
If the room's temperature and humidity are very high, some steam may escape during COOL operation. It disappears as soon as the temperature and humidity decrease.
Why is there no airflow when starting the DRY operation on my Mitsubishi Heavy Industries SRK71ZM-S Air Conditioner?
The indoor fan may stop during DRY operation to prevent re-evaporation of dehumidified moisture and to save energy.
Why RUN light stays on even though operation was stopped on my Mitsubishi Heavy Industries SRK71ZM-S?
The RUN light illuminates during CLEAN operation and turns off when CLEAN operation ends.
Why does my Mitsubishi Heavy Industries Air Conditioner fan continue to run after stopping?
The fan in your Mitsubishi Heavy Industries Air Conditioner might continue to run after you've stopped the unit for these reasons: * Indoor fan: If set to CLEAN operation, the fan will not stop after 2 hours. * Outdoor fan: The fan will not stop for about 1 minute to protect the unit.
Why is my Mitsubishi Heavy Industries SRK71ZM-S Air Conditioner not cooling properly?
If your Mitsubishi Heavy Industries Air Conditioner isn't cooling well, consider these factors: * Check if direct sunlight is entering the room. * Identify and reduce any heat sources in the room. * Consider if there are too many people in the room.
Type | Split System |
---|---|
Cooling Capacity | 7.1 kW |
Heating Capacity | 8.0 kW |
Energy Efficiency Ratio (EER) | 3.21 |
Power Supply | 220-240V, 50Hz |
Refrigerant | R410A |
Weight (Outdoor Unit) | 58 kg |
Coefficient of Performance (COP) | 3.61 |
Noise Level (Outdoor) | 52 dB(A) |