11. 
TROUBLESHOOTING 
MELSEC-A 
Character error received. 
A  character  other  than 'A  to 
Z', 
'0 
to 
S', 
' ' 
and  control codes in Section 8.4.5  (1)  ha; 
been 
tions with  the PC 
CPU. 
Buffer memory is unable to make  communica- 
The PC CPU is not  the  type  mentioned in 
Section 2.2. 
Defined PC  CPU  number do-  not exist. 
The PC CPU  number  designated  with 
the 
protocol was not  the self  (FFH)  or a station 
number set with  the MELSECNET link 
parameters. 
Incorrect  communications between  an 
AJ71C24 and a  PC  CPU. 
After the AJ71  C24  has correctly  receivod a 
request from  the computer, normal  data 
the AJ71  C24 and PC  CPU due  to noi8e or 
communications is not  performed between 
some  other  reason. 
Special function module  designation error. 
A special function module, having buffer 
communications,  is not  placed  in  the 
momory and capable 
of 
performing  data 
designated special  function module 
number's  position.  Or  the  module number 
is wrong. 
~ 
Error in  the designation of a sequence pro- 
gram  step  number. 
(1) 
A 
step number was designated  which  lies 
the PC CPU parameters. 
outside  the  program range designated by 
exist (or cannot be designated) was desig- 
nated. 
(2)  A  subsequence  program that does not 
Remote  RUN/STOP  impossible. 
ecuted from another module  (such 
as 
Remote  STOP/PAUSE  has  already  been  ex- 
another  AJ71  C24). 
Access  was  made to a station with which 
communications  has  been  discontinued. 
Memory  access to  the special function module 
cannot  be made  (for  command TR, 
TW). 
(1)  Special function module control  bus error. 
(2)  Special function module  breakdown. 
con.ctiwActkn 
Check and  correct data. 
Use  a  PC  CPU  which can per- 
form  data  communications. 
Change the PC CPU number 
to 
the self  (FFH)  or a station 
number  set  with  the MELSEC- 
NET 
link parameters, and res- 
tart  data  communications. 
Restart data communications. 
tf 
the error  recurs,  (a)  check 
for noise  and/or  other causes, 
or (b) replace the AJ71 C24. 
Restart data  communications. 
Check control  protocol data 
or  change the  special func- 
tion module  location. 
(1)  Designate  a 
step 
number 
which 
lies 
within  the 
desi 
n&drange,orchurgetk 
panmaen 
and 
restart 
trans- 
mbsion. 
(2)  Check  the  model  name 
and 
the 
set 
parameter  values 
d 
the 
corresponding PC CW. 
STOPlPAUSE from another 
Check 
for 
and reset remote 
module. 
Check the state of data  link. 
PC  CPU, 
bas. 
unit, 
special 
function  module or  AJ71C24 
hardware fault.  Consult  the 
nearest Mitsubishi  repre- 
sentative. 
(1)  Error codes OOH  to 08H  are transmitted to a  computer  after diagnosis  by an  AJ71C24, when 
(2)  Error codes  10H  to 21H  are  transmitted  from an  AJ71C24 to 
a 
computer after diagnosis  by 
access is made by  the computer to the AJ71 
C24. 
a 
PC CPU when access is made  by  an  AJ71  C24 to  the PC  CPU. 
c 
d 
n 
d 
h 
d 
Li 
n 
8, 
U 
Y 
L. 
LI 
11 
-2 
3 