6 - 17
MELSEC-A
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
No.13 Speed change program
<Speed change command pulse>
<Speed change command hold>
<New speed value setting>
<Speed change request setting>
<Speed change write>
<Speed change result read>
<Speed change command storage OFF>
<Override command pulse>
<Override value setting>
<Override value write>
No.14 Override program
No.15 Acceleration / deceleration time change program
<Acceleration / deceleration time
change program command pulse>
<Setting of acceleration time to 2000ms>
<Setting of deceleration time to without change(0)>
<Acceleration / deceleration time write>
<Acceleration / deceleration time change
enable write>
<Acceleration / deceleration time change
disable write>
<Torque change command pulse>
<Torque limit value read>
<Write to A62D/A CH.1>
No.16 Torque change program