1. To avoid unexpected falling of the corner lid, put the strap onto the corner lid's pin with turning the strap up.
2. Then hang the strap of a corner lid onto the panel’s pin.
3. Hook the corner lid claws at 3 places, and x the corner lid with attached screws.
(Wiring color: Red, Black)
(Wiring color: Red, Black)
Closing directionClosing direction
•
•
•
•
Install the grille hook securely at the panel.
The inlet grille must be installed starting from the hinge side.
Install the inlet grille securely. It may drop if it is installed insecurely.
When the stoppers have been deformed or damaged, repair them
immediately, Unless they are repaired properly, the inlet grille may
drop off.
Caution
1
For the Standard panel
1, 2
For the Draft prevention panel
(Wiring color: Red, Black)
(Wiring color: Red, Black)
1
2
(Wiring color: Blue, White)
Screw
Hook for
wiring cover
(Wiring color: Blue, White)
Motor wiring connection – Detail view
* If the wiring cover is hung at the hook
on panel, it will become easier to work.
Refrigerant
pipe
Drain pipe
Control box
9
Installing a corner lid
:
3
Removing the inlet grille
<
1
Installation of the grille hook>
<
2
Grille installation>
Install the wiring cover with care not to pinch wiring, and x it with screws.
1
<For the draft prevention panel>
1
Connect the connector of the louver motor wiring (Wiring color: Red, Black) at the panel side to the connector
CnJ3 (20 P, White) of the louver motor wiring (Wiring color: Red, Black) at the unit side.
2
Connect the connector of the air ex motor wiring (Wiring color: Blue, White) at the panel side to the connector
CnJ4 (20 P, White) of the air flex motor wiring (Wiring color: Blue, White) at the unit side.
8
Electrical wiring
The wiring work varies depending on the panel type. Select the wiring work appropriate for the panel type.
<For the standard panel>
1 Connect the connector of the louver motor wiring (Wiring color: Red, Black) at the panel side to the connector
CnJ3 (20 P, White) of the louver motor wiring (Wiring color: Red, Black) at the unit side.
Panel
Grille hook
Hinge hook
Pin
Screw
Installing the inlet grille
A
Panel setting
<Louver swing range setting (Individual louver control setting)>
It is possible to change the swing range of the louver by the wired remote control. Once the upper and lower limit
positions are set, the louver will swing within the set range.It is also possible to set the different range to each louver.
<Draft prevention setting>
The draft prevention function will not be operated if the draft prevention panel is installed and its wirings are only connected.
To operate the draft prevention function, enable the draft prevention setting by using the wired or wireless remote control.
Note: It is not possible to set by the following remote control models or older.
Wired:RC-EX3, RC-E5, RCH-E3
Wireless: RCN-E1R
Once you have enabled the settings in this mode, the draft prevention function is operated when the air-
conditioner is
started, and the parts of the draft prevention mechanism are always open when the air-conditioner is operating.
When the air-conditioner is stopped, they are closed. It is possible to enabled or disabled the draft prevention
function for each air outlet.
For the setting details, refer to the user’s manual supplied with the remote control.
7
Installing the panel
1. Temporary hanging
Lift up the hanger (2 places) on the panel for temporary support.
Hang the panel on the hook on the indoor unit.
2. Fix the panel on the indoor unit
Fasten the panel on the indoor unit with the 4 bolts supplied with the panel.
Caution
Air leakage
Air leakage along
the ceiling
Fouling
Dew condensation or dripping
Make sure no gap is left here.
Caution
Do not give any stress on the panel when adjusting the height of the indoor unit to
avoid unexpected distortion. It may cause the distortion of panel or failing to close the
inlet grille, and the parts of the draft prevention mechanism.
•
•
•
• •
Hook of the indoor unit
Temporary fixing
hanger of the panel
Temporary
fixing hanger
of the panel
Caution
If there is a gap between the ceiling and the
panel even after the xing bolts are
tightened, adjust the installation level of the
indoor unit again.
Improperly tightened xing bolts cause the
problems listed below, so make sure that bolts
are securely tightened.
Be careful not to pinch the motion sensor wiring.
The panel and the inlet grille have no directional limitation to install. (Hinges of the inlet grille can be hooked at any side.)
Install the inlet grille in the reverse order of the steps described at .
1 Attach the fall grille hook to the panel.
2 Insert the hinges of inlet grille in the insert holes on the panel.
Close then the inlet grille while pressing the stoppers (2 places).
Conrm that both stoppers are inserted securely in the panel.
6
Orientation of the panel installation
Take note that there is an orientation to install the panel.
Install the panel with the orientation shown on the right.
CAUTION
Align the “PIPE SIDE” mark (on the panel) with the
refrigerant pipes on the indoor unit.
Align the “DRAIN” mark (on the panel) with the drain
pipe on the indoor unit.
In case the orientation of the panel is
not correct, it will lead to air leakage
and also it is not possible to connect
the motor wiring.
•
•
•
Bolt for installing the panel
①
Stopper
<Removal>
Slide
Move it in the arrow direction,
and pull it up.
1, :
9 6
2
3
4
7
5
8
Air flex motor wiring
Slide
1
Before installation
3
Removing the inlet grille
Accessories
Follow installation manual carefully, and install the panel properly.
Check the following items.
Accessories
Note: Accessories are laid in the position removing the corner lid.
1.
2.
4
Removing the corner lid
Function
WARNING
Bolt
Strap
Screw
4 pieces
4 pieces
4 pieces
For panel installation
For avoiding the corner panel from falling
Grille
hook
1 piece For avoiding the grille from falling
For xing the corner panel
2
Checking the indoor unit installation height
Pull the corner lid toward the direction indicated by the arrow and remove it. (Same way for all 4 corner lids)
Read this manual together with the indoor unit’s installation manual.
Fasten the wiring to the terminal securely and hold the cable securely so as not to apply
unexpected stress on the terminal.
Loose connection or hold will cause abnormal heat generation or fire.
Make sure the power supply is turned off when electric wiring work.
Otherwise, electric shock, malfunction and improper running may occur.
Read this manual together with the air conditioner installation manual carefully.
Check if the opening size for the indoor unit is correct with the level gauge supplied in the indoor unit.
Check if the gap between the plane and the indoor unit is correct by inserting the level gauge into the air outlet
port of the indoor unit. (See below drawing)
Adjust the installation elevation if necessary.
Remove the level gauge before installing the panel.
If there is a height difference beyond the design limit between the installation level of the indoor unit and the
panel, the panel may be subject to excessive stress during installation and it may cause distortion and damage.
•
•
The draft prevention panel has the draft prevention mechanism. If the draft prevention panel is installed and the
draft prevention function is set, the draft prevention function will be oprerated and reduce the draft feeling.
(Refer to for details.)
•
* Caution before use
•
•
•
•
•
•
•
While placing a nger behind the stopper (2 places)
and pressing it in the direction of arrow ①, pull the
grille downward to open the grille.
Release the hooks of the inlet grille from the panel
while it is in the open position.
Accessories hoding position
Coner lid
5
Before installing the panel <Only Draft prevention panel>
PANEL INSTALLATION MANUAL
PJF012D503
201808
・Standard panel : without the draft prevention mechanism
・Draft prevention panel : with the draft prevention mechanism
1
Loosen screws (2 pcs.) on the control lid of the unit.
2
Slide the control lid in the arrow direction in the gure, and remove it.
3
Loosen screws on the wiring cover (2 places).
4
Slide the wiring cover (2 places) in the arrow direction in the gure, and remove it.
5
Disconnect the relay connector of the air ex motor wiring attached to the panel.
6
Connect the air ex motor wiring to CNJ2 (20 P, gray) on PCB in the control box of the unit.
7
Pass the air ex motor wiring as shown in the gure.
8
Install the wiring cover (1 place) with care not to pinch wiring, and x it with a screw.
9
Fix the air ex motor wiring with a band as shown in the gure.
:
Install the control lid with care not to pinch wiring, and x with screws (2 places,).
Caution
A
Panel setting
Louver
Suspension bolt
①Be careful the installation height when installing the indoor unit.
Also note that the installation height of this indoor unit is different from that of current (old) unit.
Installation height from the ceiling surface to the indoor unit.
・Old unit: 30 mm ⇒ This unit: 35 mm
②Do not attempt to move forcibly the louver and the air ex.
* Unless the indoor unit is installed at the height as specied above,
moisture may frost or condensate, staining the ceiling surface.
Be careful
the installation
height.
Air flex
The shadowed sections (8 places),
which are movable, could be
damaged if they are moved forcibly.
Be careful handling when holding the
panel.
Keep the distance
between 35 – 39 mm.
Exceeding the range of
distance may cause
failure, etc.
Keep the distance
between 35 – 39 mm.
Exceeding the range of
distance may cause
failure, etc.
Suspension
fixture
Ceiling
surface
Ceiling
surface
Old unit
Suspension
fixture
Indoor unit
<In case of other than the system ceiling>
<In case of the system ceiling>
35
+4
0
Ceiling board
T bar
Ceiling surface
Level gauge
(Insert in the indoor unit.)
35
+4
0
Level gauge
(Insert in the indoor unit.)
130
50
or more
30
+4
0
* The air flex will not move in case of the standard panel.