123
-
'20 • KX-T-373
Up to two units of R/C can be used
at the maximum for 1 indoor unit or 1
group.
One is main R/C and the other is sub
R/C.
Operating range is different depending
on the main or sub R/C.
室内ユニット
リモコン線
無極性)
リモコン
「親
リモコン
「子」
R/C operations Main Sub
Run/Stop, Change set temp.,
speed operations
High power operation, Energy-saving operation
Silent mode control
×
Useful
functions
×
Anti draft setting
×
Timer
Favorite setting
Weekly timer
×
Home leave mode
×
External ventilation
Select the language
Silent mode control
×
Energy-saving setting
×
Filter Filter sign reset
User setting Initial settings
Administrator
settings
Permission/
Prohibition setting
×
Outdoor unit silent
mode timer
×
Setting temp. range
×
Temp increment
setting
×
Set temp. display
R/C display setting
Change administrator
password
F1/F2 function setting
○: operable ×: not operable
R/C operations Main Sub
Service
setting
Installation
settings
Installation date
×
Company information
Test run
×
Static pressure adjustment
×
Change auto-address
×
Address setting of main IU
×
IU back-up function
×
Motion sensor setting
×
R/C function
settings
Main/Sub of R/C
Return air temp.
×
R/C sensor
×
R/C sensor adjustment
×
Operation mode
×
ºC / ºF
×
Fan speed
×
External input
×
×
×
Ventilation setting
×
Auto-restart
×
Auto temp. setting
×
Auto fan speed
×
IU settings
×
Service &
Maintenance
IU address
Next service date
×
Operation data
×
Error
display
Error history
Display/erase
anomaly data
×
Reset periodical check
Saving IU settings
×
Special
settings
Erase IU address
×
CPU reset
Restore of default setting
×
Touch panel calibration
Indoor unit capacity display
×
Indoor unit
R/C
“Main”
R/C
“Sub”
R/C cable
(No polarity)
Advice: Connection to personal computer
It can be set from a personal computer via the USB port (mini-B).
Connect after removing the cover for USB port of upper case.
Replace the cover after use.
Special software is necessary for the connection.
For details, view the web site.
USB端子
Cover
USB port
Advice: Initializing of password
Administrator password (for daily setting items) and
service password (for installation, test run and maintenance) are used.
ot refeR( degnahc eb nac gnittes sihT .0000 si tluafed yrotcaf ta drowssap rotartsinimda ehT
User's Manual).
]2F[ dna ]1F[ eht nwod gnidloh yb dezilaitini eb nac ti ,nettogrof si drowssap rotartsinimda eht fI
input screen.
○Service password is “9999”, which cannot be changed.
When the administrator password is input, the service password is also accepted.
[F1] [F2] switch
Delete
Set
Back
Input 4 digit number & tap [Set]
Input password
Input the administrator password.
5 . Main/Sub setting when more than one remote control are used
When connecting two or more FDT/FDTC to one R/C, unify the panel type either to a panel with anti draft function or a standard panel.
Advice
PJZ012A171_EN.indd 8 2018/05/09 14:37:08
0 1 2 3 4
Delete
5 6 7 8 9
Set
Back