35
DRIVE THE MOTOR
3
Operation panel
3.2.4 Operation lock (Press [MODE] for a while (2s))
 Set "10 or 11" in Pr. 161, then press   for 2s to make the setting dial and key operation invalid.
 When the setting dial and key operation is invalid,  appears on the operation panel. When the setting dial and key
operation is invalid,  appears if the setting dial or key operation is performed. (When the setting dial or key
operation is not performed for 2s, the monitor display appears.)
 To make the setting dial and key operation valid again, press 
 for 2s.
Operation using the setting dial and key of the operation panel can be made invalid to prevent parameter change, and
unexpected start or frequency setting.
POINT
Set "10 or 11" (key lock valid) in Pr. 161 Frequency setting/key lock operation selection.
Operation Display 
1.
Screen at powering ON
The monitor display appears.
2. Press   to choose the PU operation mode.
PU indication is lit.
3. Press   to choose the parameter setting 
mode.
PRM indication is lit.
(The parameter number read previously
appears.)
4. Turn  until   (Pr. 160) appears.
5. Press   to read the currently set value. 
" " (initial value) appears.
6. Turn   to change it to the set value " ".
7. Press  to set.
Flicker ··· Parameter setting complete!!
8. Change   (Pr. 161) to the setting value 
of " " in the similar manner. 
(Refer to step 4 to 7.)
Flicker ··· Parameter setting complete!!
9. Press   for 2s to show the key lock mode.
Press for 2s.
Functions valid even in the 
operation lock status
Stop and reset with  .
Note
 Release the operation lock to release the PU stop by key operation.