OPERATING PROCEDURE PHOTOS
3. Removing the heat exchanger and the compressor
(
1
)
Remove the rear panel (2 screws in front, 1 screw on
the side, 3 screws in the rear). Remove the valve bed,
and open the rear panel to the rear to remove.
NOTE :
All panels are fixed by catches, and must be removed by
shifting up and down.
(
2
)
Remove the 4 screws of the right side panel and
remove it.
(
3
)
Remove the 3 screws of the rear guard and remove it.
(
4
)
Remove the 4 screws of the separator support plate
and remove it.
(
5
)
Remove the 2 screws of the motor support and
remove it.
(
6
)
Remove the 5 screws of the valve bed.
The valve bed is fixed by the catches on the right and
left sides.
Lift it to remove.
(
7
)
Remove the electrical parts box.
Disconnect the connectors from the high pressure
switch, crank case heater, shell thermo, and fan motor
lead.
(
8
)
Remove the 2 screws of the separator and remove it.
(
9
)
Remove the 2 screws of the heat exchanger and
remove it.
Detach the welded point of pipe.
(
10
)
Remove the 3 nuts of the compressor and remove it.
Detach the welded points of the compressor suction
pipe and discharge pipe.
Photo 4
Photo 5
Photo 6
Compressor
Stop valve
Charge plug
Heat exchanger
Accumulator
Screws
Screws
OB267--3.qxp 01.4.13 0:55 PM Page 62