Table 6.3 Error Code List for A2ASCPU(S1/S30) and A2USHCPU-S1 (Continue)
Error
Massage
Error
Code
(D9008)
Detailed
Error
Code
(D9091)
CPU
States
Error and Cause Corrective Action
"OPERATION
ERROR"
(Checked at
execution of
instruction.)
50
501
Stop or
Continue
(set by
para-
meter)
(1) When file registers
(R) are used,
operation is executed
outside of specified
ranges of device
numbers and block
numbers of file
registers (R).
(2) File registers are used
in the program without
setting capacity of file
registers.
Read the error step
using a peripheral
device and check
and correct
program of the
step.
502
Combination of the
devices specified by
instruction is incorrect.
503
Stored data or constant of
specified device is not in
the usable range.
504
Set number of data to be
handled is out of the
usable range.
505
(1) Station number
specified by the
, ,
instructions is
not a local station.
(2) Head I/O number
specified by the
, ,
instructions is
not of a remote
station.
Read the error step
using a peripheral
device and check
and correct
program of the
step.
506
Head I/O number
specified by the
,
, instructions is
not of a special function
module.
LEDA/BLRDP
LEDA/B
LWTP
LRDP
LWTP
LEDA/BRFRP
LEDA/BRTOP RFRP
RTOP
LEDA/BRFRP LEDA/BRTOP
RFRP RTOP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-A A1SCPUC24-R2 and is the answer not in the manual?

Mitsubishi MELSEC-A A1SCPUC24-R2 Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-A A1SCPUC24-R2
CategoryController
LanguageEnglish

Related product manuals