Details of operation
According to the rdom temperature when the operation starts, the op-
eration mode is automatically set to either COOL or DRY. However,
when operation is started again within 2 hours after it is stopped, the
same operation mode before the operation is stopped is selected. The
operation mode selected first is not changed even if the room tempera-
ture changes. If the operation mode does not match the room condition,
select the appropriate operation mode by pressing the MOr_DEbutton.
Details of auto operation
Room temperature Operation mode Target temperature
when started (initial state)
About 77 °F or higher COOL About 75 °F
About 77 F or lower DRY
_C NOTE
OOL:Whenthe roomtemperatureis 4°Fhigherthanthe settemperature,the settemperaturemay nothe changed
sincethe air conditioneris operatingto reach the target (set)temperature.In this case, pleasewait until
the roomtemperaturedropstowithin4 OFof the set temperatureand then changethe set temperature.
Details of display on the indoor unit
The operationindicatorat the rightside of the indoorunit indicates the operation state. ,_,
MS12/15/17TN _ J, t
MS09TW
.... 0;]
_,, _ _on a_or . ,
_pperati_nn _!._ Lighted o_e:!a[. In "B" Lighted
Indicator _ Notlighted [_ Not lighted
Operation indicator lamp
The following indication does not depend on the shape of lamp.
Difference between target
Indication Operation state
temperature and room temperature
........ This shows that the air conditioner is operating to reach the target About 4 °F or more
-,W,,- -,,Q,- temperature. Please wait until the target temperature is obtained.
This shows that the room temperature is approaching the
,,==_ _ About 4 °F or less
target temperature.
-- Description of"AUTO RESTART FUNCTION"
These units are equipped with an auto restart function. When the main power is turned on, the air conditioner wilt start
operation automatically in the same mode as the one set with the remote controller before the shutoff of the main power.
If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after
the main power is turned on.
If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power
comes on, in the same mode as the one set with the remote controller before the emergency operation.
If the unit is operated in "1FEEL ..." mode before power failure, the operation is not stored in the memory. In "1FEEL ..."
mode, the operation is decided by the initial room temperature at (re)start.
Since the air conditioner has been shipped from the factory with the COOL mode saved in the memory for auto restart
function, it starts cooling operation when the user turns on the main power for the first time after installation.