EasyManua.ls Logo

Mitsubishi MUZ-A09NA - Inverter and Power Board Test Points

Mitsubishi MUZ-A09NA
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54
Back side of unit
-4 14 32 50 68 84 104
0
10
20
30
40
50
60
70
80
90
100
Temperature (°F)
Ambient temperature thermistor (RT65)
Defrost thermistor (RT61)
Temperature (°F)
Discharge temperature thermistor (RT62)
32 50 68 84 104 122 140 158 176 194 212 230 248
0
100
200
300
400
500
600
700
32 50 68 84 104 122 140 158 176
0
20
40
60
80
100
120
140
160
180
200
Temperature (°F)
Fin temperature thermistor (RT64)
Resistance(k")
Resistance(k")
Resistance(k")
Output to drive
outdoor fan motor
(CN932)
Fin temperature
thermistor/RT64
(CN642)
Ambient temperature
thermistor /RT65
(CN643)
Discharge temperature
thermistor/RT62
(CN641)
Defrost thermistor/RT61
(CN641)
LEV
connector
(CN724)
208/230V AC
DB61
Connecting wire with
power P.C. board
(CN725)
Jumper wire for change
in defrost setting (JS)
Front side of unit
DB61
280V ~ 370V
DC
Smoothing capacitor
(C63C)
Smoothing capacitor
(C63A)
Smoothing capacitor
(C63B)
Rotational frequency
feedback signal of outdoor
fan motor CN931)
1(+)
2(+)
3(+)
45V
5GND
Output to
drive
compressor
(LDW,
LDV,
LDU)
LED monitor
lamp
Connector for indoor/
outdoor communication
(CN601)
(+)
(-)
1. Inverter P.C. board
MUZ-A09NA MUZ-A12NA MUZ-A15NA
MUZ-A17NA MUY-A15NA MUY-A17NA
10-6. Test point diagram and voltage
OB451--2.qxp 06.3.29 9:49 AM Page 54

Related product manuals