128
12. Removing the compressor (MC)
(1)Removetheservicepanel.(SeeFigure1)
(2)Removethetoppanel.(SeeFigure1)
(3)Remove2frontcoverpanelfixingscrews(5×12)and
removethefrontcoverpanel.(SeePhoto3)
(4)Remove2backcoverpanelfixingscrews(5×12)and
removethebackcoverpanel.
(5)Removetheelectricalpartsbox.(SeePhoto3)
(6)Remove3valvebedfixingscrews(4×10),4ballvalveand
stopvalvefixingscrews(5×16),thenremovethevalvebed.
(7)
Remove3rightsidepanelfixingscrews(5×12)intherear
oftheunitandthenremovetherightsidepanel.
(8)Remove3separatorfixingscrews(4×10)andremovethe
separator.
(9)Recoverrefrigerant.
(10)Removethe3pointsofthemotorforcompressorfixing
nutusingspanneroradjustablewrench.
(11)Removetheweldedpipeofmotorforcompressorinlet
andoutletandthenremovethecompressor.
Note: Recover refrigerant without spreading it in the air.
13. Removing the accumulator
(1)Removetheservicepanel.(SeeFigure1)
(2)Removethetoppanel.(SeeFigure1)
(3)Remove2frontcoverpanelfixingscrews(5×12)and
removethefrontcoverpanel.(SeePhoto3)
(4)Remove2backcoverpanelfixingscrews(5×12)and
removethebackcoverpanel.
(5)Removetheelectricalpartsbox.(SeePhoto3)
(6)Remove3valvebedfixingscrews(4×10),4ballvalveand
stopvalvefixingscrews(5×16),thenremovethevalvebed.
(7)
Remove3rightsidepanelfixingscrews(5×12)intherear
oftheunitandthenremovetherightsidepanel.
(8)Recoverrefrigerant.
(9)Remove2weldedpipesofaccumulatorinletandoutlet.
(10)Remove2accumulatorlegfixingscrews(4×10).
Note: Recover refrigerant without spreading it in the air.
Photo 10
Compressor
(MC)
Valvebed
Separator
Separator
fixingscrew
Accumulator
Photo 11
Valvebed
fixingscrews
Compressor
fixingnut
Accumulatorleg
fixingscrews
Accumulator
Accumulator
leg
Inlet
Outlet
Compressor
(MC)
HEADOFFICE:TOKYOBLDG.,2-7-3,MARUNOUCHI,CHIYODA-KU,TOKYO100-8310,JAPAN
CCopyright2015MITSUBISHIELECTRICCORPORATION
DistributedinAug.2015 No.OCH577REVISEDEDITION-A
DistributedinJan.2015 No.OCH577
MadeinJapan
Newpublication,effectiveAug.2015
Specificationsaresubjecttochangewithoutnotice.