SERVICE MANUAL
No. OCH424
REVISED EDITION-D
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
R410A
November 2010
Outdoor unit
[Model names]
PUHZ-P200YHA
PUHZ-P250YHA
PUHZ-P200YHA3
PUHZ-P250YHA3
[Service Ref.]
PUHZ-P200YHA
PUHZ-P250YHA
PUHZ-P200YHA3
PUHZ-P200YHA3R1
PUHZ-P200YHA3R2
PUHZ-P200YHA3R3
PUHZ-P250YHA3
PUHZ-P250YHA3R1
PUHZ-P250YHA3R2
PUHZ-P250YHA3R3
PUHZ-P200YHA3R1/R2/R3
PUHZ-P250YHA3R1/R2/R3
Note:
This manual describes only
service data of the outdoor
units.
RoHS compliant products
have <G> mark on the
spec name plate.
CONTENTS
1. TECHNICAL CHANGES
.................................
2
2. REFERENCE MANUAL
..................................
2
3. SAFETY PRECAUTION
..................................
3
4. FEATURES
......................................................
6
5. SPECIFICATIONS
...........................................
7
6. DATA
...............................................................
8
7. OUTLINES AND DIMENSIONS
....................
10
8. WIRING DIAGRAM
.......................................
12
9. WIRING SPECIFICATIONS
..........................
13
10.
REFRIGERANT SYSTEM DIAGRAM
...............
18
11. TROUBLESHOOTING
...................................
20
12. FUNCTION SETTING
....................................
70
13.
MONITORING THE OPERATION DATA BY THE REMOTE CONTROLLER
....
77
14. EASY MAINTENANCE FUNCTION
..............
87
15. DISASSEMBLY PROCEDURE
.....................
90
PARTS CATALOG (OCB424)
Revision:
PUHZ-P200/250YHA3R3
have been added in
REVISED EDITION-D.
Some descriptions have
been modified.
Please void OCH424
REVISED EDITION-C.

Questions and Answers:

Mitsubishi PUHZ-P200YHA Specifications

General IconGeneral
BrandMitsubishi
ModelPUHZ-P200YHA
CategoryAir Conditioner
LanguageEnglish

Summary

SAFETY PRECAUTIONS

ALWAYS OBSERVE FOR SAFETY

General safety guidelines to follow before and during repair service.

CAUTIONS RELATED TO NEW REFRIGERANT

Specific safety measures for handling R410A refrigerant and related tools.

TECHNICAL SPECIFICATIONS AND DATA

UNIT SPECIFICATIONS

Detailed technical data for outdoor units, including electrical, physical, and refrigerant piping information.

REFRIGERANT CHARGE DATA

Table detailing refrigerant charge amounts based on piping length for R410A.

COMPRESSOR AND NOISE DATA

Compressor technical data and noise criterion curves for operational analysis.

INSTALLATION AND WIRING

OUTLINES AND DIMENSIONS

Guidelines for unit installation space, foundation, and piping/wiring directions.

WIRING DIAGRAMS AND SPECIFICATIONS

Electrical wiring diagrams, specifications, and M-NET wiring methods for proper system connection.

REFRIGERANT SYSTEM AND TEST RUN

REFRIGERANT SYSTEM DIAGRAM

Visual representation of the refrigerant circuit for cooling and heating operations.

TEST RUN PROCEDURES

Instructions for performing test runs on indoor and outdoor units to verify operation.

TROUBLESHOOTING AND DIAGNOSTICS

GENERAL TROUBLESHOOTING GUIDE

Actions for recurring and non-recurring troubles based on error codes and unit conditions.

SELF-DIAGNOSIS PROCEDURES

Methods for initiating and interpreting self-diagnosis results to identify system faults.

ERROR CODE ANALYSIS AND ACTION TABLE

Detailed breakdown of error codes, symptoms, and corrective actions for system troubleshooting.

FUNCTION SETTINGS AND MONITORING

UNIT FUNCTION SETTING VIA REMOTE CONTROLLER

Guide to configuring unit functions using wired and wireless remote controllers.

OPERATION DATA MONITORING

Procedure for accessing and viewing operational data, request codes, and system settings via the remote controller.

MAINTENANCE AND DISASSEMBLY

EASY MAINTENANCE FUNCTION

Utilizing maintenance mode for easier inspection and operation checks of the unit.

DISASSEMBLY PROCEDURES

Step-by-step instructions for safely disassembling unit components for maintenance or repair.