OUTDOOR UNIT
PUHZ-RP250YHM-A
For use with R410A
INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
GB
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi PUHZ-RP250YHM-A and is the answer not in the manual?

Mitsubishi PUHZ-RP250YHM-A Specifications

General IconGeneral
BrandMitsubishi
ModelPUHZ-RP250YHM-A
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

Before Installation and Electric Work

Essential safety checks before commencing installation and electrical work.

Precautions for Devices That Use R410A Refrigerant

Specific safety measures required when working with R410A refrigerant systems.

Lifting Method

Installation of Unit

Installation

General instructions and requirements for the physical installation of the outdoor unit.

Refrigerant Piping Installation

Either a Lack or an Excess of Refrigerant Causes the Unit to Make an Emergency Stop. Charge the System with an Appropriate Amount of Refrigerant.

Importance of correct refrigerant charge levels for proper system operation and preventing shutdowns.

Never Use Refrigerant to Perform an Air Purge. Always Evacuate Using a Vacuum Pump.

Mandates vacuum pump evacuation over refrigerant purging for system integrity.

Additional Refrigerant Charge

Precautions Concerning Piping Connection and Valve Operation

Detailed steps and safety measures for connecting refrigerant pipes and operating valves.

After Completing Work, Tighten the Service Port and Cap Securely So as Not to Generate Any Gas Leakage.

Final step to ensure the service port is sealed properly to prevent refrigerant leaks.

Airtight Test, Evacuation, and Refrigerant Charging

Airtight Test

Procedures for performing an airtightness test on the refrigerant circuit.

Airtight Test Procedure

Step-by-step instructions for conducting the airtight test.

Evacuation

Process for evacuating the system using a vacuum pump to remove air and moisture.

Never Perform Air Purging Using Refrigerant.

Reinforces the rule against using refrigerant for air purging.

Thermal Insulation of Refrigerant Piping

Wiring

Caution

Important safety and regulatory guidelines for electrical wiring.

Wiring of Main Power Supply and Equipment Capacity

Guidance on main power supply wiring, circuit breakers, and system capacity.

Warning

Critical warnings regarding secure wiring connections and proper overcurrent protection.

Test Run