Check code
Abnormal point and detection method
Case
Judgment and action
U8
(4400)
Outdoor fan motor
Abnormaliftherotationalfrequencyoffan
motorisnotdetectedduringDCfanmotor
operation.
Fanmotorrotationalfrequencyisabnor-
malif;
•100rpmorbelowdetectedcontinuously
for15secondsat68˚F[20:]ormore
outsideairtemperature.
•50rpmorbelowor1500rpmormore
detectedcontinuouslyfor1minute.
1Failureintheoperationofthe
DCfanmotor
2Failureintheoutdoorcircuit
controllerboard
1CheckorreplaceDCfanmotor.
2Checkthevoltageoftheoutdoorcircuit
controllerboardduringoperation.
3Replaceoutdoorcontrollercircuitboard.
(whenthefailureisstillindicatedeven
afterperformingtheaction1above.)
U9
(4220)
Tofindoutthedetailhistory(latest)aboutU9error,turnONSW2-1,2-2and2-6.
Referto"10-10.FUNCTIONOFSWITCHES,CONNECTORSANDJUMPERS".
1Checkthefieldfacilityforthepowersupply.
2Correctthewiring(U
.
V
.
Wphase)to
compressor.
Referto"10-9.TESTPOINT
DIAGRAM"(Outdoorpowercircuitboard).
3Replaceoutdoorpowercircuitboard.
4Checkcompressorforelectricalinsulation.
Replacecompressor.
1Decreaseinpowersource
voltage,instantaneousstop.
2Disconnectionorloose
connectionofCN52Conthe
outdoorpowercircuitboard/
controllercircuitboard
3Defectiveconverterdrivecircuit
inoutdoorpowercircuitboard
4Defective52Cdrivecircuitin
outdoorpowercircuitboard
5Disconnectionorloose
connectionofCN2onthe
outdoorpowercircuitboard/
controllercircuitboard
6PowercircuitfailureonDC
supplyfor18VDCoutputon
outdoorcontrollercircuitboard
04
Input current sensor error/
L1-phase open error
•Decreaseininputcurrent
throughoutdoorunitto0.1A
onlyifoperationfrequencyis
morethanorequalto40Hz
orcompressorcurrentismore
thanorequalto6A.
1Defectiveinputcurrentdetection
circuitinoutdoorpowercircuit
board
2Defectiveoutdoorcontroller
circuitboard
1Replaceoutdoorpowercircuitboard.
2Replaceoutdoorcontrollercircuitboard.
Detailed
codes
01
Overvoltage error
•IncreaseinDCbusvoltageto
A12,18,24N:420V
A30,36,42N:400V
1Abnormalincreaseinpower
sourcevoltage
2Disconnectionofcompressor
wiring
3Defectiveoutdoorpowercircuit
board
4Compressorhasagroundfault.
02
Undervoltage error
•InstantaneousdecreaseinDC
busvoltageto200V
1Checkthefieldfacilityforthepowersupply.
2CheckCN52Cwiring.
3Replaceoutdoorpowercircuitboard.
4Replaceoutdoorpowercircuitboard.
5CheckCN2wiring.
6Replaceoutdoorcontrollercircuitboard.
08
Abnormal power synchronous
signal
•Noinputofpowersynchronous
signaltopowercircuitboard
•Powersynchronoussignal
of44Hzorless,or65Hzor
moreisdetectedonpower
circuitboard.
1Disconnectionorloose
connectionofearthwiring
2Defectivepowersynchronous
signalcircuitinoutdoor
controllercircuitboard
3Defectivepowersynchronous
signalcircuitinoutdoorpower
circuitboard
1Checkearthwiring.
2Replaceoutdoorcontrollercircuitboard.
3Replaceoutdoorpowercircuitboard.
10
PFC error (Overvoltage/
Undervoltage/Overcurrent)
(A12–24N only)
•PFCdetectedanyofthefol-
lowing:
a)IncreaseofDCbusvoltage
to420V.
b)DecreaseinPFCcontrol
voltageto12VDCorlower.
c)Increaseininputcurrentto
47Apeak.
1Distortionofpowersource
voltage,noisesuperimposition
2Disconnectionorloose
connectionofCN2ontheoutdoor
powercircuitboard/controller
circuitboard
3DefectivePFCmoduleofoutdoor
powercircuitboard
1Checkthefieldfacilityforthepower
supply.
2CheckCN2wiring.
3Replace