3 - 38 3 - 38
MELSEC-Q
3 SPECIFICATIONS
(b) REMFR/REMTO/READ/WRITE instructions
REMFR/REMTO/READ/WRITE instructions transmission delay time is the
sum of the following.
• Remote master station scan time (Except for the link refreshing time)
• Remote master station refresh time
• Link scan time
Calculate the sum as shown below:
[Instruction transmission delay time (M
D
)]
[Remote master station scan time (Sm) > link scan time (LS)]
M
D
= (Sm + αm) 3 [ms]
0E
Sm
α
m
LS
Remote master station
Link scan time
Remote I/O station
Instruction
0E
Sm
α
m
0E
Sm
α
m
0E
Sm
α
m
0E
Sm
α
m
0E
Sm
α
m
0E
Sm
α
m
0E
Sm
α
m
0E
Sm
α
m
0E
Sm
α
m
0E
Sm
α
m
LSLSLSLS
M
D
M
rα
Instruction execution
0: 0 step
E: END step
Completion flag ON
[Remote master station scan time (Sm) < link scan time (LS)]
M
D
= (Sm + αm) round up [LS/(Sm + αm)] 3 [ms]
LS
Remote master station
Link scan time
Remote I/O station
M
d
Instruction
M
rα
Completion flag ON
Instruction execution
0E
Sm
αm
0E
Sm
αm
0E
Sm
αm
0E
Sm
αm
0E
Sm
αm
0E
Sm
LS LS LS LS
0: 0 step
E: END step
Sm
αm
LS
Mrα
round up
: Remote master station scan time
: Remote master station link refresh time
: Link scan time
: Instruction access data refresh time
: Round up the decimal point of the result operation [LS/(Sm + αm)]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi QJ71LP21-25 and is the answer not in the manual?

Mitsubishi QJ71LP21-25 Specifications

General IconGeneral
BrandMitsubishi
ModelQJ71LP21-25
CategoryController
LanguageEnglish

Related product manuals