EasyManua.ls Logo

Mitsubishi QJ71LP21 - User Manual

Mitsubishi QJ71LP21
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
(Remote I/O network)
Q Corresponding MELSECNET/H Network System Reference Manual(Remote I/O network)
R
Q Corresponding MELSECNET/H
Network System
Q Corresponding MELSECNET/H
Network System
Reference Manual (Remote I/O network) Reference Manual
Mitsubishi Programmable
Logic Controller
MODEL
MODEL
CODE
Q-NET/H-R-I/O-E
13JF96
SH(NA)-080124-G(0503)MEE
QJ71LP21
QJ71LP21-25
QJ71LP21S-25
QJ71LP21G
QJ71LP21GE
QJ71BR11
QJ72LP25-25
QJ72LP25G
QJ72LP25GE
QJ72BR15
Y
Specifications subject to change without notice.
When exported from Japan, this manual does not require application to the
Ministry of Economy, Trade and Industry for service transaction permission.
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN
NAGOYA WORKS : 1-14 , YADA-MINAMI 5-CHOME , HIGASHI-KU, NAGOYA , JAPAN

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi QJ71LP21 and is the answer not in the manual?

Mitsubishi QJ71LP21 Specifications

General IconGeneral
BrandMitsubishi
ModelQJ71LP21
CategoryController
LanguageEnglish

Summary

Q Corresponding MELSECNET;H Network System Reference Manual (Remote I;O network)

Safety Precautions

Provides essential safety instructions and warnings before operating the equipment.

1 Overview

1.2 Features

Details the key features of the MELSECNET/H remote I/O network system, including communication speed and system configuration.

2 System Configuration

2.1 Single Remote I;O Networks

Details the configuration of single remote I/O networks using optical loop and coaxial cable systems.

2.2 Multiple Remote I;O Network (QnPHCPU Only)

Describes the configuration of multiple remote I/O networks using the QnPHCPU, including master and sub-master stations.

2.3 Multiplexed Remote I;O Network for Redundant System (QnPRHCPU Only)

Explains the multiplexed remote I/O network configuration for redundant systems using QnPRHCPU.

2.4 Multiple Remote I;O Network

Details the configuration of multiple remote I/O networks, allowing multiple networks to be connected.

3 Specifications

3.2.2 RAS functions

Details RAS (Reliability, Availability, Serviceability) functions, including output reset and automatic return.

4 Setup and Procedures Before Starting the Operation

4.1 Procedures Before Starting the Operation

Provides a flowchart of the procedures required to perform data link operations.

4.7 Standalone Check of the Network Module (Offline Tests)

Explains offline tests for checking network module hardware and cable connections.

4.9 Offline Tests from GX Developer

Details offline tests performed using GX Developer to check cable connection status.

4.10 Network Diagnostics from GX Developer (Online Test)

Explains how to use GX Developer for online network diagnostics to check line status.

5 Parameter Settings

5.1 Remote Master Station Parameter Setting

Details parameter settings for the remote master station, including network type and common parameters.

5.1.7 Redundant settings

Details settings for redundant systems, ensuring consistent modes between master and sub-master stations.

5.2 Remote I;O Station Parameter Settings

Covers settings for remote I/O modules, including PLC parameters, network parameters, and remote passwords.

5.2.1 Remote I;O station possible parameter settings

Lists the parameters that can be set on the remote I/O station and written to the remote I/O module.

6 Programming

6.1 Programming Precautions

Provides precautions for creating programs using network data, focusing on interlock signals.

7 Application Functions

7.10 Multiplexed Remote Master Function (QnPHCPU Only)

Allows multiplexed remote sub-master station to take control when the master station fails.

7.11 Multiplexed Remote Master Function for the Redundant System (QnPRHCPU Only)

Details the multiplexed remote master function for redundant systems, covering backup and switching functions.

7.11.1 Backup function of master operation on system switching between control system and standby system

Explains the backup function of master operation during system switching between control and standby systems.

7.12 Remote Password

Explains the remote password function to prevent unauthorized access to remote I/O modules and PLC CPUs.

8 Troubleshooting

8.1 Network Diagnostics (Network Monitor)

Details how to check network status using GX Developer's network diagnostic function.

8.1.4 Error history monitor

Checks the status of forward/reverse loop errors, communication errors, and transient transmission errors.

8.2 Troubleshooting

Provides a systematic approach to troubleshooting network and module issues.

8.2.1 Items to be checked first

Lists critical items to check first when troubleshooting network modules and data link issues.

8.2.7 When a multiplexed remote I;O network for the redundant system does not operate normally

Troubleshoots issues with redundant multiplexed remote I/O networks not operating correctly.

8.3 Error Codes

Lists MELSECNET/H error codes, their descriptions, and corrective actions.

8.3.1 MELSECNET;H error code list

Provides a detailed list of MELSECNET/H error codes, their meanings, causes, and corrective measures.

Related product manuals