1 - 1 1 - 1
MELSEC-Q
1 OVERVIEW
1 OVERVIEW
The MELSECNET/H system includes the following 2 types of networks:
1) PLC to PLC network for communications between a control station and normal
stations
2) Remote I/O network for communications between a remote master station and
remote I/O stations
This is the manual to read when building a remote I/O network for MELSECNET/H
systems (hereafter called MELSECNET/H). If you are building a MELSECNET/H
network for PLC to PLC network, please refer to the Q-corresponding MELSECNET/H
network system reference manual. (PLC to PLC network) (SH-080049)
POINT
The Q00JCPU, Q00CPU and Q01CPU cannot configure a remote I/O network in a
MELSECNET/H network system.
REMARK
The previous network, called MELSECNET/10H is now called MELSECNET/H.
1.1 Overview
The MELSECNET/H remote I/O network system has more functionality and capacity
than the former network system, MELSECNET/10 network system (hereafter referred
to as MELSECNET/10).
As the MELSECNET/H remote I/O network adopts the same module mounting method
as the usual one (mounting I/O modules and intelligent function modules onto the main
base unit/expansion base unit), each module mounted on the remote I/O stations can
be handled in the similar way as the basic one.
In addition, the applicability to the MELSECNET/10 remote I/O network has been
further enhanced so that the FA system can be easily configured.
In the MELSECNET/H remote I/O network optical loop system, the communication
speed can be set to 25 Mbps or 10 Mbps.
Network system Communication speed
Optical loop 1 25 Mbps
MELSECNET/H
Optical loop, coaxial cable 10 Mbps
1: QJ71LP21-25, QJ71LP21S-25, QJ72LP25-25 only
Remote I/O station
QCPU
GX Developer
Control station (MELSECNET/10 mode)
Control station (MELSECNET/H mode)
GX Developer
QCPU normal station
QCPU normal station
QCPU normal station
Remote I/O station Remote I/O station Remote I/O station
MELSECNET/H (25Mbps)
PC network
Remote master station
MELSECNET/H (10Mbps)
remote I/O network
MELSECNET/H (25Mbps) remote I/O network
MELSECNET/H (10Mbps)
PLC to PLC network
QnACPU
normal station
AnUCPU
normal station
QCPU
normal station
1