(8)  Outline of automatic operation
 (a)   Determination of operation mode
 The unit checks the room temperature, determines the operation mode, and then begins in the automatic operation.
(7)  Outline of cooling operation
       (a)   Operation of major functional components in cooling mode
 (b)   Fan speed switching
 (b)
  The unit checks the temperature every 30 minutes after the start of operation and, if the result of check is not same as the 
previous operation mode, changes the operation mode.
 (c)   
 When the unit is started again within 30 minutes after the stop of automatic operation or when the automatic operation is 
selected during cooling or dehumidifying operation, the unit is operated in the previous operation mode.
 (d)
 Setting temperature can be adjusted within the following range. There is the relationship as shown below between the sig
-
nals of the wireless remote control and the setting temperature.
           
 Signals of wireless remote control (Display)
     
–6  –5  –4  –3  –2  –1 
±
0  +1  +2  +3  +4  +5  +6
 
Setting
 
Cooling
  18  19  20  21  22  23  24  25  26  27  28  29  30
 
temperature
 
Dehumidifying
  18  19  20  21  22  23  24  25  26  27  28  29  30
Operation mode
Room temperature
<
26
℃
26
℃≦
Room temperature
Dehumidifying Cooling