Do you have a question about the Moen INS10477 and is the answer not in the manual?
Brand | Moen |
---|---|
Model | INS10477 |
Category | Garbage Disposal |
Language | English |
Unplug or turn off power, disconnect drain line from disposal discharge tube.
If installed, unplug or turn off power and remove dishwasher drain hose.
Support disposal, turn lower mounting ring to remove from sink flange.
Turn off power, disconnect hardwired connections or unplug unit.
Connect disposal cord to 110-120V AC outlet; ensure proper grounding.
Turn lower mount ring to disengage from ramps; loosen screws to move ring.
Use screwdriver to remove snap ring, then remove mounting ring, backup flange, and fiber gasket.
Re-assemble fiber gasket, backup flange, and mounting ring onto sink flange.
Clean drain area, apply plumber's sealant, position sink flange, and apply weight.
Pull snap ring open and press into groove to secure mounting parts.
Tighten three 1/2" screws evenly against backup flange, do not overtighten.
Install new discharge elbow/gasket assembly, tighten screws, do not overtighten.
Knock out dishwasher inlet plug using blunt instrument, remove gasket from elbow.
Check that lower mounting ring and cushioning mount are engaged on disposal.
Align discharge elbow and hang disposal by aligning tabs with slide-up ramps.
Turn lower mounting ring until tabs lock over ramps; use screwdriver for leverage if needed.
Reconnect discharge elbow to drain line, secure with wrench, check for leaks.
Connect dishwasher hose using clamp; use a dishwasher connector kit if hose size differs.
Ensure proper grounding for safety; use grounded plug-in cord and appropriate outlet.
Connect to 110-120V AC, use factory plug-in cord, ensure proper outlet and switch.
Run cold water, turn on switch, scrape garbage, run water after use.
Ensure disposal is empty before dishwasher use, leave stopper in drain when not in use.
Motor is permanently lubricated; do not attempt to lubricate or use chemical cleaners.
Address foreign objects, humming noises, and unit not starting by checking reset button and wiring.
Check for lodged objects, ensure proper seating of flange, elbow, and hose connections.