15
Code
Function
Settings and options
Default
1
Temperature
compensation
-9 - 9 °C (for internal sensor)
-3
2
Deadzone temperature
1 5 °C
1
3
Button locking
00: All buttons are locked except power
button
01: All buttons are locked
01
4
Sensor types
In: Internal sensor (to control the temperature)
Ou: External sensor (to control the
temperature)
AL: Internal/external sensor (internal sensor to
control the temperature, external sensor to
limit the temperature)
AL
5
Minimal set
temperature
5 15 °C
05
6
Maximal set
temperature
15 45 °C
35
7
Display mode
00: Display both set temperature and room
temperature
01: Display set temperature only
00
8
Low temperature
protection settings
0 10 °C
00
9
High temperature
protection settings
25 70 °C
45
A
Economy mode
00: Non-energy saving mode
01: Energy saving mode
0
B
Economy temperature
0 30 °C
20