N
The Printer Applicators are released for 110-volt sales only.
N
You can use thermal direct printing (no ribbon) or thermal
transfer printing (with ribbon).
N
The Printer Applicators do not support continuous
(non-indexed) supplies.
Printer Configuration Information
The default configuration packet settings are:
{
I
,A,0,0,0,0,0
p
B,3,1,1,0,0
p
C,0,0,0,0,0,0
p
D,1,0,2
p
E,{,,,",
p
~,--,--,Od/Oa
p
F,1,1,0,0,3
p
G,1,95,95
p
}
The supply type must be center aperture (3).
Backfeed must be enabled (1). The dispense
position when and backfeed distances must be set to
95 dots using 1/8-inch gap supplies.
Status Polling Information
ENQ Response Meaning
??
Powerup
A@
Online/Ready to receive data after label
has been applied
C@
Label is printing
CH
Label is printed
SB
Out of supplies
SD
Out of ribbon
E-4