Options for the EN Input include:
Change motor speed - when the input is closed, the motor will run at a different speed which
must be entered in the change motor speed to box
Enable motor when closed - the motor is enable when current is owing through the input and
has no power when the input is open
Enable motor when open - opposite of above
Reset alarm when closing – an alarm or fault can be cleared by closing the input
Reset alarm when opening - an alarm or fault can be cleared by opening the input
Not Used – there is no function for the input, but its state can be read using the SCL IS, FS or
FY command.
Options for Output are:
Closed on fault – the output will close if a fault occurs
Open on fault - the output will open if a fault occurs
Closed to release brake – the output controls a fail safe brake relay
Open to release brake - the output opens to release the brake
Closed when moving - the output closes whenever motor is moving
Open when moving - the output opens whenever motor is moving
Tach out – the output produces pulses relative to the motor position
Not Used – there is no function for the output, but it can be controlled using the SCL SO, FO,
IH and IL commands.
SCL Mode
Here the power up mode for the drive is set correctly for use with SCL applications.
SCL is MOONS’ host command language for applications requiring drives to receive instructions
from a host controller in real time. With SCL, drives can be operated in RS-232 mode.
SCL Address