5. Fire Blazing Out Of Control
Check that:
The door or doors are correctly closed.
The door seals are in good condition.
The main body gaskets are in good condition. With the stove running trace along the
joints of the stove with a burning incense stick; if the smoke trail is drawn into the stove at
any point it would indicate a defective seal.
Important note: All Morsø stoves use the same ceramic rope gasket for doors and main body
castings. The use of unauthorised non Morsø gaskets during routine maintenance commonly
results in:
Pressure on the casting and fixing point which can lead to cracking.
Inability to fit components due to insufficient compression of the gasket.
Inability to close the door or excessive force required to close the door resulting in dam -
age to both the door casting and the glass.
The following kits are available from your authorised Morsø dealer:
Sealing rope 2mtr x Ø8mm (doors & body parts) 62903100
Sealing kit for doors and bogy parts with adhesive 62904300
Self adhesive ladder gasket for glass 2mtr x 8mm 62903800
Glass kit 1410 inc gasket, clips & screws 62904000
Glass kit 1440 inc gasket, clips & screws 62904100
Glass kit 1430 inc gasket, clips & screws 62904200