5. Fire Blazing Out Of Control
Check that:
• The door or doors are correctly closed.
• The door seals are in good condition.
• The main body gaskets are in good condition. With the stove running trace along the
joints of the stove with a burning incense stick; if the smoke trail is drawn into the stove at
any point it would indicate a defective seal.
Important note: All Morsø stoves use the same ceramic rope gasket for doors and main body
castings. The use of unauthorised non Morsø gaskets during routine maintenance commonly
results in:
• Pressure on the casting and fixing point which can lead to cracking.
• Inability to fit components due to insufficient compression of the gasket.
• Inability to close the door or excessive force required to close the door resulting in dam -
age to both the door casting and the glass.
The following kits are available from your authorised Morsø dealer:
• Sealing rope 2mtr x Ø8mm (doors & body parts) 62903100
• Sealing kit for doors and bogy parts with adhesive 62904300
• Self adhesive ladder gasket for glass 2mtr x 8mm 62903800
• Glass kit 1410 inc gasket, clips & screws 62904000
• Glass kit 1440 inc gasket, clips & screws 62904100
• Glass kit 1430 inc gasket, clips & screws 62904200